Refrigerant Circuit Pressure Sensor -G805-, Removing And Installing: Removing
Immediately seal off any open lines and connections with clean plugs from the Engine Bung Set: VAS 6122 .
Continuation
-- Loosen the coolant expansion tank and move to the side. Refer to COOLANT EXPANSION TANK, REMOVING AND INSTALLING .
-- Disconnect the connector -1-.
-- Check the refrigerant line connection and the Refrigerant Circuit Pressure Sensor -G805- -2- for dirt and clean them.
Danger of frostbite due to refrigerant coming out under pressure.
Frostbite on the skin and other parts of the body is possible.
- Wear safety gloves.
- Wear protective eyewear.
- If refrigerant flows out of the refrigerant line longer than one second when loosening the pressure sensor, tighten the pressure sensor and replace the faulty check valve.
- Evacuate or drain refrigerant and open the refrigerant circuit immediately.
-- Remove the sensor -2- using the Socket - 24mm: T40284 .