LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Volkswagen >> 2017 >> e-Golf SE >> Repair and Diagnosis >> External Pages >> Different car >> Section 1248 (Climate Control System - General Information (2 Of 2)) >> Diagnosis And Testing >> Climate Control System >> Pinpoint Test(s) >> Pinpoint Test M : Air Discharge Temperature Sensor Circuit Faults >> Notes
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Pinpoint Test M : Air Discharge Temperature Sensor Circuit Faults: Notes

WARNING: This page is about a different car, the 2018 Lincoln Navigator. However, it is still accessible from the selected car via links, so may be relevant.

Refer to Wiring Diagrams Automatic Climate Control System for schematic and connector information.

Normal Operation and Fault Conditions 

The 4 air discharge temperature sensors contain a thermistor. The sensor varies its resistance with the temperature. As the temperature rises, the resistance falls. As the temperature falls, the resistance rises. REFER to: Climate Control System - System Operation and Component Description .

DTC Fault Trigger Conditions 

DTC Description Fault Trigger Conditions
B10B3:11 Right Panel Air Discharge Temperature: Circuit Short To Ground This DTC sets when the FCIM senses erratic voltages from the right panel air discharge temperature sensor.
B10B3:15 Right Panel Air Discharge Temperature: Circuit Short To Battery or Open This DTC sets when the FCIM senses erratic voltages from the right panel air discharge temperature sensor.
B10B4:11 Right Floor Air Discharge Temperature: Circuit Short To Ground This DTC sets when the FCIM senses erratic voltages from the right panel air discharge temperature sensor.
B10B4:15 Right Floor Air Discharge Temperature: Circuit Short To Battery or Open This DTC sets when the FCIM senses erratic voltages from the right panel air discharge temperature sensor.
B10B5:11 Left Panel Air Discharge Temperature: Circuit Short To Ground This DTC sets when the FCIM senses erratic voltages from the left panel air discharge temperature sensor.
B10B5:15 Left Panel Air Discharge Temperature: Circuit Short To Battery or Open This DTC sets when the FCIM senses erratic voltages from the left panel air discharge temperature sensor.
B10B6:11 Left Floor Air Discharge Temperature: Circuit Short To Ground This DTC sets when the FCIM senses erratic voltages from the left floor air discharge temperature sensor.
B10B6:15 Left Floor Air Discharge Temperature: Circuit Short To Battery or Open This DTC sets when the FCIM senses erratic voltages from the left floor air discharge temperature sensor.

Possible Sources