USB Connection BASEPLATE -R193-, Troubleshooting

WARNING: This page is about a different variant/trim than selected.

Special tools and workshop equipment required 

The USB connection is not capable of On Board Diagnostics (OBD).

The voltage supply can be checked at the connector.

Test Conditions 

Procedure 

-- Remove the USB connection baseplate. Refer to USB CONNECTION BASEPLATE -R193- .

-- Disconnect the connector under the USB connection baseplate.

-- Turn on the radio/RNS

-- Measure the voltage between contacts 3 and 6 as well as between contacts 3 and 8 on the wiring harness connector using V.A.G 1526C and the cables from the V.A.G 1594C.

Specified value: approximately 12 V.

-- Turn off the radio/RNS.

Voltage values not OK:

-- Check the wire connections between the radio and the USB connection baseplate according to the wiring diagram.

Voltage values OK: