| P2BA7 |
NOx Exceedence - Empty Reducing Agent Tank |
Refill with AdBlue® fluid and recheck system. |
- Calculated urea tank level = 0
|
--- |
Continuous |
|
| P20A0 |
Reductant Purge Control Valve Circuit Open |
-- Check the Reduction Agent Reversing Valve. Refer to REDUCTION AGENT REVERSING VALVE CHECKING |
- Diagnostic signal from power stage > 4.5 V
|
|
480 mSec. |
|
| P20A2 |
Reductant Purge Control Valve Circuit Low |
-- Check the Reduction Agent Reversing Valve. Refer to REDUCTION AGENT REVERSING VALVE CHECKING |
- Diagnostic signal from power stage < 2.97 V
|
|
480 mSec. |
|
| P20A3 |
Reductant Purge Control Valve Circuit High |
-- Check the Reduction Agent Reversing Valve. Refer to REDUCTION AGENT REVERSING VALVE CHECKING |
- Diagnostic signal from power stage > 2.2 A
|
|
480 mSec. |
|
| P20BB |
Reductant Heater "A" Control Circuit Low |
Heating 1 circuit is the tank heater. No tank module assembly components are serviced separately (at the time of writing). Replacement of the Reducing Agent Tank Module assembly is necessary if the tank module power and grounds are present, and no heater connection faults exist between the heating module (on the side of the tank) and the tank heating element connectors. |
- Diagnostic signal from power stage < 2.97 V
|
|
480 mSec. |
|
| P20BC |
Reductant Heater "A" Control Circuit High |
Heating 1 circuit is the tank heater. No tank module assembly components are serviced separately (at the time of writing). Replacement of the Reducing Agent Tank Module assembly is necessary if the tank module power and grounds are present, and no heater connection faults exist between the heating module (on the side of the tank) and the tank heating element connectors. |
- Diagnostic signal from power stage > 2.2 A
|
|
480 mSec. |
|
| P20BD |
Reductant Heater "B" Control Circuit/Open |
-- Check the Reducing Agent Wire Heater. Refer to REDUCTION AGENT HEATED SUPPLY LINE CHECKING |
- Diagnostic signal from power stage > 4.5 V
|
|
480 mSec. |
|
| P20BF |
Reductant Heater "B" Control Circuit Low |
-- Check the Reducing Agent Wire Heater. Refer to REDUCTION AGENT HEATED SUPPLY LINE CHECKING |
- Diagnostic signal from power stage < 2.97 V
|
|
480 mSec. |
|
| P20B5 |
Reductant Metering Unit Heater Control Circuit/Open |
-- Check the Reducing Agent Wire Heater. Refer to REDUCTION AGENT HEATED SUPPLY LINE CHECKING |
- Current during heating < 2 A
|
|
1000 mSec. |
|
| P20B7 |
Reductant Metering Unit Heater Control Circuit Low |
-- Check the Reducing Agent Wire Heater. Refer to REDUCTION AGENT HEATED SUPPLY LINE CHECKING |
- Max. power at engagement < 5 A
|
- Time since engagement > 10 Sec.
|
--- |
|
| P20B9 |
Reductant Heater "A" Control Circuit/Open |
Heating 1 circuit is the tank heater. No tank module assembly components are serviced separately (at the time of writing). Replacement of the Reducing Agent Tank Module assembly is necessary if the tank module power and grounds are present, and no heater connection faults exist between the heating module (on the side of the tank) and the tank heating element connectors. |
- Diagnostic signal from power stage > 4.5 V
|
|
480 mSec. |
|
| P20C0 |
Reductant Heater "B" Control Circuit High |
-- Check the Reducing Agent Wire Heater. Refer to REDUCTION AGENT HEATED SUPPLY LINE CHECKING |
- Diagnostic signal from power stage > 2.2 A
|
|
480 mSec. |
|
| P20EE |
SCR NOx Catalyst Efficiency Below Threshold Bank 1 |
-- Check the Reduction Agent Injector --. Refer to REDUCTION AGENT INJECTOR CHECKING |
- Difference between calculated and measured efficiency > 0.25
|
- Status NOx Sensor Downstream = ready
- Status NOx Sensor Upstream = ready
- Urea dosing = active
- Adaptation = not active
- DPF regeneration = not active
- SCR Catalyst temp gradient < 0.2 to 0.34 K/s
- SCR catalyst modeled temp. = 240 - 350 °C
- NOx concentration upstream < 1500 ppm.
|
Integrated NOx Mass flow upstream >=0.4g |
|
| P20E8 |
Reductant Pressure Too Low |
-- Check the Reduction Agent Pressure Sensor. Refer to REDUCTION AGENT PRESSURE SENSOR CHECKING |
- Pressure built up for 45 attempts < 3500 hPa
or
- Actual pressure < 3000 hPa or Target - Actual pressure > 1500 hPa
|
- SCR system state = pressure control
or
- SCR system state = metering control
|
100 Sec. or 500 mSec. |
|
| P20E9 |
Reductant Pressure Too High |
-- Check the Reduction Agent Pressure Sensor. Refer to REDUCTION AGENT PRESSURE SENSOR CHECKING |
- Pressure at dosing end > 500 hPa after 10 Sec.
or
- Actual pressure > 7900 hPa or Target - Actual pressure < -1500 hPa
|
- SCR system state = pressure reduction
or
- SCR system state = metering control
|
10000 mSec. or 5000 mSec. |
|
| P2002 |
Particulate Trap Bank 1 Efficiency Below Threshold |
-- Check the Exhaust Pressure Sensor -G450-. Refer to EXHAUST PRESSURE SENSOR 1 CHECKING . If the pressure sensors are OK, a Service Bay Regeneration should be performed using a VAS 5052 (available for rental) or equivalent scan tool |
- Differential pressure < f (volumetric flow rate, soot load)
OR
- Differential pressure < f (volumetric flow rate)
|
- Calculated temperature of diesel particulate filter between 250 - 450 °C
- Calculated DPF loading > 11g
- Exhaust gas flow rate < 300 (m3/h)
- T ambient (T1) > -7 °C
OR
- Exhaust volumetric flow rate > 400 (m3/h)
- Delta exhaust volumetric flow rate < (20) (m3/h)s
- Within 1 Sec. time period
|
2 Sec. |
OR
|
| P2004 |
Intake Manifold Runner Control Bank 1 Stuck Open |
-- Check the Intake Flap Motor --. Refer to INTAKE MANIFOLD FLAP MOTOR AND RUNNER POSITION SENSOR 1-2 CHECKING . |
- Control deviation > 10%
- Actual position <= 40%
|
--- |
14000 mSec. |
|
| P2005 |
Intake Manifold Runner Control Bank 2 Stuck Open |
-- Check the Intake Flap Motor --. Refer to INTAKE MANIFOLD FLAP MOTOR AND RUNNER POSITION SENSOR 1-2 CHECKING . |
- Control deviation > 10%
- Actual position <= 40%
|
--- |
14000 mSec. |
|
| P2006 |
Intake Manifold Runner Control Bank 1 Stuck Closed |
-- Check the Intake Flap Motor --. Refer to INTAKE MANIFOLD FLAP MOTOR AND RUNNER POSITION SENSOR 1-2 CHECKING . |
- Control deviation > 10%
- Actual position > 40%
|
--- |
14000 mSec. |
|
| P2007 |
Intake Manifold Runner Control Bank 2 Stuck Closed |
-- Check the Intake Flap Motor --. Refer to INTAKE MANIFOLD FLAP MOTOR AND RUNNER POSITION SENSOR 1-2 CHECKING . |
- Control deviation > 10%
- Actual position > 40%
|
--- |
14000 mSec. |
|
| P2008 |
Intake Manifold Runner Control Bank 1 Stuck Open |
-- Check the Intake Flap Motor --. Refer to INTAKE MANIFOLD FLAP MOTOR AND RUNNER POSITION SENSOR 1-2 CHECKING . |
- Diagnostic signal from power stage > 0.8 V (output 1) and < 2 V (output 2)
OR
- Diagnostic signal from power stage = 8 to 18 A
OR
- Diagnostic signal from power stage > 5 V or < 3.4 V
|
OR
|
OR
|
|
| P2009 |
Intake Manifold Runner Bank 1 Control Circuit Low |
-- Check the Intake Flap Motor --. Refer to INTAKE MANIFOLD FLAP MOTOR AND RUNNER POSITION SENSOR 1-2 CHECKING . |
Diagnostic signal from power stage 8 to 18 A |
Power stage = On state |
480 mSec. |
|
| P2010 |
Intake Manifold Runner Control Circuit High, Bank 1 |
-- Check the Intake Flap Motor --. Refer to INTAKE MANIFOLD FLAP MOTOR AND RUNNER POSITION SENSOR 1-2 CHECKING . |
Diagnostic signal from power stage = 8 to 18 A |
Power stage = On state |
480 mSec. |
|
| P2011 |
Intake Manifold Runner Bank 2 Control Circuit Stuck Open |
-- Check the Intake Flap Motor --. Refer to INTAKE MANIFOLD FLAP MOTOR AND RUNNER POSITION SENSOR 1-2 CHECKING . |
- Diagnostic signal from power stage > 0.8 V (output 1) and < 2 V (output 2)
OR
- Diagnostic signal from power stage = 8 to 18 A
OR
- Diagnostic signal from power stage > 5 V or < 3.4 V
|
OR
|
OR
|
|
| P2012 |
Intake Manifold Runner Bank 2 Control Circuit Low |
-- Check the Intake Flap Motor --. Refer to INTAKE MANIFOLD FLAP MOTOR AND RUNNER POSITION SENSOR 1-2 CHECKING . |
Diagnostic signal from power stage 8 to 18 A |
Power stage = On state |
480 mSec. |
|
| P2013 |
Intake Manifold Runner Bank 2 Control Circuit High |
-- Check the Intake Flap Motor --. Refer to INTAKE MANIFOLD FLAP MOTOR AND RUNNER POSITION SENSOR 1-2 CHECKING . |
Diagnostic signal from power stage = 8 to 18 A |
Power stage = On state |
480 mSec. |
|
| P2015 |
Intake Manifold Runner Position Sensor Circuit Range/Performance |
-- Check the Intake Flap Motor --. Refer to INTAKE MANIFOLD FLAP MOTOR AND RUNNER POSITION SENSOR 1-2 CHECKING . |
- Position sensor signal < 3550 mV
- Position sensor signal > 1450 mV
OR
- Position sensor signal > 550 mV and < 250 mV
OR
- Position sensor signal > 4450 mV and < 4750 mV
|
- ECT > -30 °C and < 120 °C
- IAT > 0 and < 80 °C
|
200 mSec. |
|
| P2016 |
Intake Manifold Runner Position Sensor Circuit Low |
-- Check the Intake Flap Motor --. Refer to INTAKE MANIFOLD FLAP MOTOR AND RUNNER POSITION SENSOR 1-2 CHECKING . |
Position sensor signal <= 250 mV |
--- |
480 mSec. |
|
| P2017 |
Intake Manifold Runner Position Sensor Circuit High |
-- Check the Intake Flap Motor --. Refer to INTAKE MANIFOLD FLAP MOTOR AND RUNNER POSITION SENSOR 1-2 CHECKING . |
Position sensor signal >= 4750 mV |
--- |
480 mSec. |
|
| P202A |
Reductant Tank Heater Control Circuit/Open |
Check the tank connections, and power and grounds to the Reduction Agent Tank Module. If all voltage and ground inputs to the module are present, Replace the Reduction Agent Tank Module assembly. |
- Current during heating < 2 A
|
|
1000 mSec. |
|
| P202B |
Reductant Tank Heater Control Circuit Low |
Check the tank connections, and power and grounds to the Reduction Agent Tank Module. If all voltage and ground inputs to the module are present, Replace the Reduction Agent Tank Module assembly. |
- Max. power at engagement < 3 W
|
- Time since engagement > 10 Sec.
|
--- |
|
| P202C |
Reductant Tank Heater Control Circuit High |
Check the tank connections, and power and grounds to the Reduction Agent Tank Module. If all voltage and ground inputs to the module are present, Replace the Reduction Agent Tank Module assembly. |
- Max. power at engagement > 14 W
|
- Time since engagement > 10 Sec.
|
--- |
|
| P2020 |
Intake Manifold Runner Position Sensor Circuit Bank 2 Range/Performance |
-- Check the Intake Flap Motor -V157-. Refer to INTAKE MANIFOLD FLAP MOTOR AND RUNNER POSITION SENSOR 1-2 CHECKING . |
- Position sensor signal < 3550 mV
- Position sensor signal > 1450 mV
OR
- Position sensor signal > 550 mV and < 250 mV
OR
- Position sensor signal > 4450 mV and < 4750 mV
|
--- |
200 mSec. |
|
| P2021 |
Intake Manifold Runner Position Sensor Circuit Bank 2 Low |
-- Check the Intake Manifold Runner Position Sensor Bank 2. Refer to INTAKE MANIFOLD FLAP MOTOR AND RUNNER POSITION SENSOR 1-2 CHECKING |
Position sensor signal <= 250 mV |
--- |
480 mSec. |
|
| P2022 |
Intake Manifold Runner Position Sensor Circuit Bank 2 High |
-- Check the Intake Flap Motor -V157-. Refer to INTAKE MANIFOLD FLAP MOTOR AND RUNNER POSITION SENSOR 1-2 CHECKING . |
Position sensor signal >= 4750 mV |
--- |
480 mSec. |
|
| P203A |
Reductant Level Sensor Circuit |
Check the Reduction Agent Tank connections, and power and grounds to the Reduction Agent Tank Module. If all voltage and ground inputs to the module are present and no connection faults are found, Replace the Reduction Agent Tank Module assembly. |
or
|
- SCR tank temperature > -3 °C
- If SCR tank temp < -3 °C then defrosting urea tank = done
- Time until release of metering unit heating < 600 Sec.
|
50 mSec. |
|
| P203B |
Reductant Level Sensor Circuit Range/Performance |
Check the Reduction Agent Tank connections, and power and grounds to the Reduction Agent Tank Module. If all voltage and ground inputs to the module are present and no connection faults are found, Replace the Reduction Agent Tank Module assembly. |
or
|
- SCR tank temperature > -3 °C
- If SCR tank temp < -3 °C then defrosting urea tank = done
- Time until release of metering unit heating < 600 Sec.
|
50 mSec. |
|
| P2031 |
Exhaust Gas Temperature Sensor 2 Circuit |
-- Check the Exhaust Gas Temperature Sensor --. Refer to EXHAUST GAS TEMPERATURE SENSOR 1- 4 CHECKING . |
Signal voltage > 1652 mV |
--- |
480 mSec. |
|
| P2032 |
Exhaust Gas Temperature Sensor 2 Circuit Low |
-- Check the Exhaust Gas Temperature Sensor --. Refer to EXHAUST GAS TEMPERATURE SENSOR 1- 4 CHECKING . |
Signal voltage < 330 mV |
--- |
480 mSec. |
|
| P204A |
Reductant Pressure Sensor Circuit |
-- Check the Reduction Agent Pressure Sensor --. Refer to REDUCTION AGENT PRESSURE SENSOR CHECKING . |
|
--- |
480 mSec. |
|
| P204B |
Reductant Pressure Sensor Circuit Range/Performance |
-- Check the Reduction Agent Pressure Sensor --. Refer to REDUCTION AGENT PRESSURE SENSOR CHECKING . |
|
--- |
480 mSec. |
|
| P204D |
Reductant Pressure Sensor Circuit High |
-- Check the Reduction Agent Pressure Sensor --. Refer to REDUCTION AGENT PRESSURE SENSOR CHECKING . |
- Actual pressure before pressure build up > 500 hPa
|
- T6 > 100 °C
- Ambient temperature > -3 °C
- Urea tank temperature > -7 °C
- Engine speed > 800 rpm
|
200 mSec. |
|
| P2047 |
Reductant Injection Valve Circuit/Open Bank 1 Unit 1 |
-- Check the Reduction Agent Injector --. Refer to REDUCTION AGENT INJECTOR CHECKING |
- Diagnostic signal from power stage > 4.5 V
|
|
48 Sec. |
|
| P2048 |
Reductant Injection Valve Circuit Low Bank 1 Unit 1 |
-- Check the Reduction Agent Injector --. Refer to REDUCTION AGENT INJECTOR CHECKING |
- Diagnostic signal from power stage < 2.97 V
or
|
or
|
48 Sec. |
|
| P2049 |
Reductant Injection Valve Circuit High Bank 1 Unit 1 |
-- Check the Reduction Agent Injector --. Refer to REDUCTION AGENT INJECTOR CHECKING |
- Diagnostic signal from power stage > 2.2 A
or
|
|
48 Sec. |
|
| P205A |
Reductant Tank Temperature Sensor Circuit |
-- Check the Reducing Agent Tank Temperature Sensor --. Refer to REDUCTION AGENT TEMPERATURE SENSOR CHECKING |
|
--- |
480 mSec. |
|
| P205B |
Reductant Tank Temperature Sensor Circuit Range/Performance |
-- Check the Reducing Agent Tank Temperature Sensor --. Refer to REDUCTION AGENT TEMPERATURE SENSOR CHECKING |
- Absolute value of temperature difference to ECT > 30 °K
|
- Engine off time > 9 hr
- Rising of urea temperature within 25 minutes < 1.5 °K
|
480 mSec. |
|
| P205C |
Reductant Tank Temperature Sensor Circuit Low |
-- Check the Reducing Agent Tank Temperature Sensor --. Refer to REDUCTION AGENT TEMPERATURE SENSOR CHECKING |
|
--- |
480 mSec. |
|
| P208A |
Reductant Pump "A" Control Circuit/Open |
Check the power and grounds to the Reduction Agent Tank Module. If all voltage and ground inputs to the module are present, Replace the Reduction Agent Tank Module assembly. |
- Deviation between actual and nominal control value > 0.75%
|
--- |
480 mSec. |
|
| P208C |
Reductant Pump "A" Control Circuit Low |
Check the power and grounds to the Reduction Agent Tank Module. If all voltage and ground inputs to the module are present, Replace the Reduction Agent Tank Module assembly. |
- Diagnostic signal from power stage permanently <.46 uV
|
--- |
480 mSec. |
|
| P208D |
Reductant Pump "A" Control Circuit High |
Check the power and grounds to the Reduction Agent Tank Module. If all voltage and ground inputs to the module are present, Replace the Reduction Agent Tank Module assembly. |
- Diagnostic signal from power stage permanently >.6 uV
|
--- |
480 mSec. |
|
| P208E |
Reductant Injection Valve Stuck Closed Bank 1 Unit 1 |
-- Check the Reduction Agent Injector --. Refer to REDUCTION AGENT INJECTOR CHECKING |
- Missing number of signal peaks > 50
|
- Urea dosing = active
- Ambient pressure = 700 - 1300 hPa
- SCR urea pressure = 3500 - 6500 hPa
- Dosing valve coil temperature = 10 - 20 °C
|
25 - 500 Sec. |
|
| P2080 |
Exhaust Gas Temperature Sensor Circuit Range/Performance |
-- Check the Exhaust Gas Temperature Sensor --. Refer to EXHAUST GAS TEMPERATURE SENSOR 1- 4 CHECKING . |
- Temperature difference to temp EGR T3, T4, T5, T6 > 60 °K
or
- Mean value of modeled to measured T4 > 100 °K
|
- Engine off time > 9 hr
- Decrease of IAT and T2 < 5 °K at > 25 mph for 20 Sec.
- Decrease of AAT after engine start < 5 °K for 60 Sec.
|
20 Sec. with speed above 25 mph |
|
| P2084 |
Exhaust Gas Temperature Sensor 2 Circuit Range/Performance |
-- Check the Exhaust Gas Temperature Sensor --. Refer to EXHAUST GAS TEMPERATURE SENSOR 1- 4 CHECKING . |
- Temperature difference to temp EGR T3, T4, T5, T6 > 60 °K
or
- Mean value of modeled to measured T3 > 100 °K
|
- Engine off time > 9 hr
- Decrease of IAT and T2 < 5 °K at > 25 mph for 20 Sec.
- Decrease of AAT after engine start < 5 °K for 60 Sec.
|
20 Sec. with speed above 25 mph |
|
| P2100 |
Throttle Actuator Control Motor Circuit/Open |
-- Check the Throttle Valve Control Module -J338-. Refer to THROTTLE VALVE CONTROL MODULE, CHECKING . |
Signal from power stage > 3.26 V and < 5.40 V |
Power stage = Off state |
During ECM keep alive time |
|
| P2101 |
Throttle Actuator Control Motor Circuit Range/performance |
-- Check the Throttle Valve Control Module -J338-. Refer to THROTTLE VALVE CONTROL MODULE, CHECKING . |
Signal = no change |
--- |
ECM initialization time |
|
| P2102 |
Throttle Actuator Control Motor Circuit Low |
-- Check the Throttle Valve Control Module -J338-. Refer to THROTTLE VALVE CONTROL MODULE, CHECKING . |
Signal from power stage <= 3.26 V |
Power stage = Off state |
During ECM keep alive time |
|
| P2103 |
Throttle Actuator "A" Control Motor Circuit High |
-- Check the Throttle Valve Control Module -J338-. Refer to THROTTLE VALVE CONTROL MODULE, CHECKING . |
Signal from power stage > 1.50 V and > 50 mA |
Power stage = On state |
480 mSec. |
|
| P2122 |
Throttle/Pedal Position Sensor D Circuit Low Input |
-- Check the Throttle Position (TP) Sensor -G79- /Accelerator Pedal Position Sensor 2 -G185-. Refer to THROTTLE POSITION SENSOR/ACCELERATOR PEDAL POSITION SENSOR 2, CHECKING . |
Signal voltage < 0.646 V |
--- |
200 mSec. |
|
| P2123 |
Throttle/Pedal Position Sensor D Circuit High Input |
-- Check the Throttle Position (TP) Sensor -G79- /Accelerator Pedal Position Sensor 2 -G185-. Refer to THROTTLE POSITION SENSOR/ACCELERATOR PEDAL POSITION SENSOR 2, CHECKING . |
Signal voltage > 4.889 V |
--- |
200 mSec. |
|
| P2127 |
Throttle/Pedal Position Sensor E Circuit Low Input |
-- Check the Throttle Position (TP) Sensor -G79- /Accelerator Pedal Position Sensor 2 -G185-. Refer to THROTTLE POSITION SENSOR/ACCELERATOR PEDAL POSITION SENSOR 2, CHECKING . |
Signal voltage < 0.276 V |
--- |
200 mSec. |
|
| P2128 |
Throttle/Pedal Position Sensor E Circuit High Input |
-- Check the Throttle Position (TP) Sensor -G79- /Accelerator Pedal Position Sensor 2 -G185-. Refer to THROTTLE POSITION SENSOR/ACCELERATOR PEDAL POSITION SENSOR 2, CHECKING . |
Signal voltage > 2.644 V |
--- |
200 mSec. |
|
| P2138 |
Throttle/Pedal Position Sensor D/E Circuit Voltage Correlation |
-- Check the Throttle Position (TP) Sensor -G79- /Accelerator Pedal Position Sensor 2 -G185-. Refer to THROTTLE POSITION SENSOR/ACCELERATOR PEDAL POSITION SENSOR 2, CHECKING . |
- Signal voltage sensor 1 vs. sensor 2 > 143 - 260 mV
|
- Signal voltage sensor 1 > 445 mV
- Sensor 2 > 445 mV
- Limp in mode = inactive
|
430 mSec. |
|
| P2146 |
Fuel Injector Group "A" Supply Voltage Circuit Open |
-- Check Fuel Injectors -N30, N31, N32, N33, N83, N84-. Refer to FUEL INJECTORS, CHECKING . |
Diagnostic signal from power stage = internal signal |
Injection signal = injector On |
4 injections |
|
| P2152 |
Fuel Injector Group "C" Supply Voltage Circuit/Open |
-- Check Fuel Injectors -N30, N31, N32, N33, N83, N84-. Refer to FUEL INJECTORS, CHECKING . |
Diagnostic signal from power stage = internal signal |
Injection signal = injector On |
4 injections |
|
| P2183 |
Engine Coolant Temperature Sensor 2 Circuit Range/Performance |
-- Check the Engine Coolant Temperature (ECT) Sensor 2 -G83-. Refer to ENGINE COOLANT TEMPERATURE SENSOR 2, CHECKING . |
- Temperature difference to ECT > 30 °K
- Temperature difference to T2, FTS > 35 °K
- Temperature difference to T1 > 40 °K
|
- Engine off time > 9 hr
- Decrease of IAT and T2 < 5 °K at > 25 mph for 20 Sec.
- Decrease of AAT after engine start < 5 °K for 60 Sec.
|
20 Sec. with speed above 25 mph |
|
| P2184 |
Engine Coolant Temperature Sensor 2 Circuit Low |
-- Check the Engine Coolant Temperature (ECT) Sensor 2 -G83-. Refer to ENGINE COOLANT TEMPERATURE SENSOR 2, CHECKING . |
Signal voltage < 162 mV |
--- |
480 mSec. |
|
| P2185 |
Engine Coolant Temperature Sensor 2 Circuit High |
-- Check the Engine Coolant Temperature (ECT) Sensor 2 -G83-. Refer to ENGINE COOLANT TEMPERATURE SENSOR 2, CHECKING . |
Signal voltage > 3255 mV |
--- |
480 mSec. |
|
| P2195 |
O2 Sensor Signal Stuck Lean Bank 1 Sensor 1 |
-- Check the Heated Oxygen Sensor (HO2S) -G39-. Refer to OXYGEN SENSOR BEFORE CATALYTIC CONVERTER, CHECKING . |
- Measured oxygen concentration @ fuel cutoff > 25.6%
OR
- Measured oxygen concentration @ part load > (calculated) 6.5%
|
- Engine in fuel cutoff
- EGR valve closed
- Heater control = active
- DPF regeneration = not active
- Air mass > 250 mg/stroke
- Integrated air mass flow > 180 g
- Engine speed > 1100 rpm
OR
- Heater control = active
- DPF regeneration = not active
- Fuel mass < 5 - 14 mg/stroke
- Air mass > 250 mg/stroke
- Integrated air mass flow > 180 g
- Engine speed 630 - 850 rpm
|
OR
|
|
| P2196 |
O2 Sensor Signal Stuck Rich Bank 1 Sensor 1 |
-- Check the Heated Oxygen Sensor (HO2S) -G39-. Refer to OXYGEN SENSOR BEFORE CATALYTIC CONVERTER, CHECKING . |
- Measured oxygen concentration @ fuel cutoff > 14.7%
|
- Engine in fuel cutoff
- EGR valve closed
- Heater control active
- DPF regeneration inactive
- Air mass > 250 mg/stroke
- Integrated air mass flow > 180g
- Engine speed > 1100 rpm
|
5 -10 Sec. |
|
| P22A0 |
NOx Sensor Bank 1 Sensor 2 Circuit Low |
-- Check the NOx Sensor Module --. Refer to NOX SENSOR MODULE 1 - 2, CHECKING . |
|
- Dewpoint exceeded
- NOx control = active
|
2 Sec. |
|
| P22A1 |
NOx Sensor Bank 1 Sensor 2 Circuit High |
-- Check the NOx Sensor Module --. Refer to NOX SENSOR MODULE 1 - 2, CHECKING . |
|
- Dewpoint exceeded
- NOx control = active
|
2 Sec. |
|
| P22A7 |
NOx Sensor Heater Sense Bank 1 Sensor 2 Circuit Range/Performance |
-- Check the NOx Sensor Module --. Refer to NOX SENSOR MODULE 1 - 2, CHECKING . |
- NOx control = not active after > 400 Sec.
|
- Exhaust temperature upstream SCR = 100 - 600 °C
- Dewpoint exceeded
|
1 Sec. |
|
| P220A |
NOx Sensor Supply Voltage Bank 1 Sensor 1 Circuit |
-- Check the NOx Sensor Module --. Refer to NOX SENSOR MODULE 1 - 2, CHECKING . |
- Sensor supply voltage > 1.5 or < 12 V
|
|
2 Sec. |
|
| P220B |
NOx Sensor Supply Voltage Bank 1 Sensor 2 Circuit |
-- Check the NOx Sensor Module --. Refer to NOX SENSOR MODULE 1 - 2, CHECKING . |
- Sensor supply voltage > 1.5 or < 12 V
|
|
2 Sec. |
|
| P2200 |
NOx Sensor Bank 1 Sensor 1 Circuit |
-- Check the NOx Sensor Module --. Refer to NOX SENSOR MODULE 1 - 2, CHECKING . |
- Exhaust temperature upstream SCR = 100 - 600 °C
- Dewpoint exceeded
- Measured A/F ratio (O2S) > 1
- NOx control = 1st activation
- Exhaust temperature upstream SCR 100 - 600 °C
- Steady state condition (actual filtered A/F ratio) O2S < 0 - 0.2 for 5 Sec.
|
|
|
|
| P2201 |
NOx Sensor Circuit Range/Performance Bank 1 Sensor 1 |
-- Check the NOx Sensor Module --. Refer to NOX SENSOR MODULE 1 - 2, CHECKING . |
- NOx 40 - 70%, time > 5 Sec. or 40% value not reached within 7 Sec.
- Ratio > 3 or < -0.75
- Average NOx Offset value > 50 or < -30 ppm
|
- NOx sensor heater control = active
- Fuel cutoff = active
- DPF regeneration = not active
- Time since last DPF regeneration > 60 Sec.
- Fuel quantity > 10 mg/stroke
- Air mass = 250 - 450 mg/stroke
- EGR sensor closed or position 70 - 90%
- Engine speed 1300 - 1800 rpm
- ECT > 65 °C
- Exhaust gas temp upstream catalyst > 80 °C
- Time since engine start > 120 Sec.
- Calculated NOx value = 50 - 250 ppm
- Ambient temp = 7 - 50 °C
- Zero Fuel calibration = not active
|
6 - 7.5 Sec. |
|
| P2202 |
NOx Sensor Bank 1 Sensor 1 Circuit Low |
-- Check the NOx Sensor Module --. Refer to NOX SENSOR MODULE 1 - 2, CHECKING . |
|
- Dewpoint exceeded
- NOx control = active
|
2 Sec. |
|
| P2203 |
NOx Sensor Bank 1 Sensor 1 Circuit High |
-- Check the NOx Sensor Module --. Refer to NOX SENSOR MODULE 1 - 2, CHECKING . |
|
- Dewpoint exceeded
- NOx control = active
|
2 Sec. |
|
| P2209 |
NOx Sensor Heater Sense Bank 1 Sensor 1 Circuit Range/Performance |
-- Check the NOx Sensor Module --. Refer to NOX SENSOR MODULE 1 - 2, CHECKING . |
- NOx control = not active after > 400 Sec.
|
- Exhaust temperature upstream SCR = 100 - 600 °C
- Dewpoint exceeded
|
1 Sec. |
|
| P2237 |
O2 Sensor Positive Current Control Circuit Bank 1 Sensor 1 Open |
-- Check the Heated Oxygen Sensor (HO2S) -G39-. Refer to OXYGEN SENSOR BEFORE CATALYTIC CONVERTER, CHECKING . |
- Measured oxygen concentration < 0.005
|
- Fuel cutoff = not active
- Time since last fuel cutoff > 30 Sec.
- Calibration of internal resistance or O2 = not active
- Modeled O2 concentration > 0.067 for 2 Sec.
- O2 heater temp > 720 and < 840 °C
- Dewpoint exceeded
- Reference pump current = active
- Oxygen pump current = active
- Engine operation mode = normal for > 200 mSec.
- Regeneration = not active
|
2 Sec. |
|
| P2243 |
O2 Sensor Reference Voltage Circuit Bank 1 Sensor 1 Open |
-- Check the Heated Oxygen Sensor (HO2S) -G39-. Refer to OXYGEN SENSOR BEFORE CATALYTIC CONVERTER, CHECKING . |
- O2S internal resistance > 3 V
- Oxygen signal < -1.3 V or > 1.5 V
|
- Fuel cutoff = not active
- Time since last fuel cutoff > 30 Sec.
- Calibration of internal resistance or O2 = not active
- Heater control = active for > 10 Sec.
- Dewpoint exceeded
|
2 Sec. |
|
| P2251 |
O2 Sensor Negative Current Control Circuit Bank 1 Sensor 1 open |
-- Check the Heated Oxygen Sensor (HO2S) -G39-. Refer to OXYGEN SENSOR BEFORE CATALYTIC CONVERTER, CHECKING . |
- O2S internal resistance > 3 V
- Oxygen signal > -0.1 V and < 0.1 V
|
- Fuel cutoff = not active
- Time since last fuel cutoff > 30 Sec.
- Calibration of internal resistance or O2 = not active
- Heater control = active for > 10 Sec.
- Dewpoint exceeded
|
2 Sec. |
|
| P2263 |
Turbocharger/Supercharger Boost System Performance |
-- Check the Heated Oxygen Sensor (HO2S) -G39-. Refer to TURBOCHARGER CONTROL MODULE CHECKING . |
Control deviation > 8% |
--- |
3100 mSec. |
|
| P2264 |
Boost Pressure Actuator Position Sensor Low |
-- Check the Heated Oxygen Sensor (HO2S) -G39-. Refer to TURBOCHARGER CONTROL MODULE CHECKING . |
Position sensor signal < 150 mV |
--- |
1300 mSec. |
|
| P2265 |
Boost Pressure Actuator Position Sensor High |
-- Check the Heated Oxygen Sensor (HO2S) -G39-. Refer to TURBOCHARGER CONTROL MODULE CHECKING . |
Position sensor signal > 4848 mV |
--- |
1300 mSec. |
|
| P2279 |
Intake Air System Leak |
Check for leaking engine gaskets, oil cap not installed properly or leak in the intake duct after the Mass Air Flow sensor. |
Ratio of measured and modeled mass air flow < 0.45 |
- Ambient pressure > 50 kPa
- Engine speed 1000 - 4000 RPM
- Boost pressure < 200 kPa
- Fuel quantity > 0 mg/stroke
|
3 Sec. |
|
| P229E |
NOx Sensor Bank 1 Sensor 2 Circuit |
-- Check the NOx Sensor Module --. Refer to NOX SENSOR MODULE 1 - 2, CHECKING . |
- NOx sensor status ratio > 0.5
|
- Exhaust temperature upstream SCR 100 - 600 °C
- Measured A/F ratio (O2S) > 1
- NOx control = 1st activation
- Dewpoint exceeded
- Steady state condition (actual filtered A/F ratio (O2S)) 0 - 0.2 for > 5 Sec.
|
3 - 15 Sec. |
|
| P229F |
NOx Sensor Circuit Range/Performance Bank 1 Sensor 2 |
-- Check the NOx Sensor Module --. Refer to NOX SENSOR MODULE 1 - 2, CHECKING . |
- Delta of NOx value downstream SCR <= 5 ppm after peak detection of NOx value upstream
- Number of checks = 2
OR
- Average NOx Offset value > 50 or < -30 ppm
|
- NOx sensor heaters = active
- NOx sensor upstream rationality check = tested
- Engine speed 1000 - 3500 rpm
- Time since engine start = 120 Sec.
- Calculated exhaust gas mass flow < 150 kg/hr
- Measured NOx value upstream < 175 ppm stable for 1 Sec.
- Calculated exhaust mass flow > 400 kg/hr
- OR measured NOx value upstream > 600 ppm for 2.5 Sec.
- Zero fuel calibration = not active
|
2 consecutive 5.5 Sec intervals |
|
| P2294 |
Fuel Pressure Regulator 2 Control Circuit |
-- Check the Fuel Pressure Regulator Metering Valve 2 -N290-. Refer to FUEL PRESSURE REGULATOR METERING VALVE 2 CHECKING . |
Diagnostic signal from power stage < 2.97 V |
Power stage = Off state |
0.29 Sec. |
|
| P2295 |
Fuel Pressure Regulator 2 Control Circuit Low |
-- Check the Fuel Pressure Regulator Metering Valve 2 -N290-. Refer to FUEL PRESSURE REGULATOR METERING VALVE 2 CHECKING . |
Diagnostic signal from power stage > 4.5 V |
Power stage = Off state |
0.22 Sec. |
|
| P2296 |
Fuel Pressure Regulator 2 Control Circuit High |
-- Check the Fuel Pressure Regulator Metering Valve 2 -N290-. Refer to FUEL PRESSURE REGULATOR METERING VALVE 2 CHECKING . |
Diagnostic signal from power stage > 2.7 A |
Power stage = On state |
0.29 Sec. |
|
| P242A |
Exhaust Gas Temperature Sensor Circuit Bank 1 Sensor 3 |
-- Check the Exhaust Gas Temperature Sensor --. Refer to EXHAUST GAS TEMPERATURE SENSOR 1- 4 CHECKING . |
Signal voltage > 1652 mV |
--- |
480 mSec. |
|
| P242B |
Exhaust Gas Temperature Sensor Circuit Bank 1 Sensor 3 Range/Performance |
-- Check the Exhaust Gas Temperature Sensor --. Refer to EXHAUST GAS TEMPERATURE SENSOR 1- 4 CHECKING . |
- Temperature difference to EGR temp, T3, T4, T5, T6 > 60 °K
OR
- Mean value of modeled - measured T5 > 100 °K
|
--- |
300 Sec. |
|
| P242C |
Exhaust Gas Temperature Sensor Circuit Low Bank 1 Sensor 3 |
-- Check the Exhaust Gas Temperature Sensor --. Refer to EXHAUST GAS TEMPERATURE SENSOR 1- 4 CHECKING . |
Signal voltage < 330 mV |
--- |
480 mSec. |
|
| P2425 |
Exhaust Gas Recirculation Cooling Valve Control Circuit Open |
-- Check the EGR Cooler Switch Over Valve --. Refer to EGR COOLER SWITCH OVER VALVE 1-2 CHECKING . |
Diagnostic signal from power stage > 4.5 V |
Power stage = Off state |
480 mSec. |
|
| P2426 |
Exhaust Gas Recirculation Cooling Valve Control Circuit Low |
-- Check the EGR Cooler Switch Over Valve --. Refer to EGR COOLER SWITCH OVER VALVE 1-2 CHECKING . |
Diagnostic signal from power stage < 2.97 V |
Power stage = Off state |
480 mSec. |
|
| P2427 |
Exhaust Gas Recirculation Cooling Valve Control Circuit High |
-- Check the EGR Cooler Switch Over Valve --. Refer to EGR COOLER SWITCH OVER VALVE 1-2 CHECKING . |
Diagnostic signal from power stage > 2.2 A |
Power stage = On state |
480 mSec. |
|
| P244C |
Exhaust Temperature Too Low For Particulate Filter Regeneration Bank 1 |
If no Exhaust Temperature Sensor codes are set, a Service Bay Regeneration should be performed using a VAS 5052 (available for rental) or equivalent scan tool |
Time to closed loop 120 - 300 Sec. |
- T5 < 350 °C
- Engine speed > 1500 rpm
- Fuel mass > 15 mg/stroke
- Regeneration with post injection = On
|
10 - 300 Sec. |
|
| P245B |
Exhaust Gas Recirculation Cooler Bypass Control Circuit Range/Performance |
-- Check the EGR Cooler Switch Over Valve --. Refer to EGR COOLER SWITCH OVER VALVE 1-2 CHECKING . |
Measured temperature < 0.8 |
- Engine speed = 1200 - 2500 rpm
- Delta engine speed = + -250 rpm
- Fuel quantity = 9 - 80 mg/stroke
- Delta fuel quantity = + -20 mg/stroke
- EGR valve > 0 85%
- Delta EGR valve = + -15%
- EGR mass flow > 30 kg/hr
- SCR temp > 150 °C
- EGR temp < 300 °C
|
11 Sec. |
|
| P2452 |
Diesel Particulate Filter Differential Pressure Sensor Circuit |
-- Check the Exhaust Pressure Sensor --. Refer to EXHAUST PRESSURE SENSOR 1 CHECKING . |
Sensor voltage > 4.9 V |
--- |
480 mSec. |
|
| P2453 |
Diesel Particulate Filter Differential Pressure Sensor Circuit Range/Performance |
-- Check the Exhaust Pressure Sensor --. Refer to EXHAUST PRESSURE SENSOR 1 CHECKING . |
- Pressure drop > 3 kPa or < -3 kPa
|
Engine Off |
5 Sec. |
|
| P2454 |
Diesel Particulate Filter Differential Pressure Sensor Circuit Low |
-- Check the Exhaust Pressure Sensor --. Refer to EXHAUST PRESSURE SENSOR 1 CHECKING . |
Sensor voltage < 0.2 V |
--- |
480 mSec. |
|
| P246E |
Exhaust Gas Temperature Sensor Circuit Bank 1 Sensor 4 |
-- Check the Exhaust Gas Temperature Sensor --. Refer to EXHAUST GAS TEMPERATURE SENSOR 1- 4 CHECKING . |
Signal voltage > 1652 mV |
--- |
480 mSec. |
|
| P246F |
Exhaust Gas Temperature Sensor Circuit Bank 1 Sensor 4 Range/Performance |
-- Check the Exhaust Gas Temperature Sensor --. Refer to EXHAUST GAS TEMPERATURE SENSOR 1- 4 CHECKING . |
- Temperature difference to EGR temp, T3, T4, T5, T6 > 60 °K
OR
- Mean value of modeled - measured T5 > 100 °K
|
--- |
300 Sec. |
|
| P2463 |
Diesel Particulate Filter - Soot Accumulation |
Service Bay Regeneration must be performed using a VAS 5052 (available for rental) or equivalent scan tool |
Calculated particulate matter trap loading > 40 g |
--- |
0.2 Sec. |
|
| P247A |
Exhaust Gas Temperature Out of Range Bank 1 Sensor 3 |
-- Check the Exhaust Gas Temperature Sensor --. Refer to EXHAUST GAS TEMPERATURE SENSOR 1- 4 CHECKING . |
Control deviation (T5) > 200 K or < -100 K |
- Regeneration with post injection = On
- Temperature controller set value > 90 or < 10%
- Fuel mass > 6 mg/stroke
- Engine speed > 1000 RPM
- T5 > 350 °C
- Temperature change T5 (absolute value) < 3 °K/Sec.
|
50 - 120 Sec. |
|
| P2470 |
Exhaust Gas Temperature Sensor Circuit Low Bank 1 Sensor 4 |
-- Check the Exhaust Gas Temperature Sensor --. Refer to EXHAUST GAS TEMPERATURE SENSOR 1- 4 CHECKING . |
Signal voltage < 330 mV |
--- |
480 mSec. |
|
| P2478 |
Exhaust Gas Temperature Out of Range Bank 1 Sensor 1 |
-- Check the Exhaust Gas Temperature Sensor --. Refer to EXHAUST GAS TEMPERATURE SENSOR 1- 4 CHECKING . |
Control deviation > limit from Map f or < limit from Map f (engine speed, torque) |
- Regeneration from PM trap = On
- Upstream turbine temperature > 350 °C
- Desired post injection > 1 mg/stroke
- Fuel quantity > 3 mg/stroke
- Engine speed 1250 - 4000 RPM
- ECT between 20 - 115 °C
- Veh speed > 35 km/h
|
30 Sec. |
|
| P2564 |
Turbocharger Boost Control Position Sensor Circuit Low |
-- Check the Turbocharger Control Module --. Refer to TURBOCHARGER CONTROL MODULE CHECKING . |
Sensor signal voltage < 0.15 V |
--- |
480 mSec. |
|
| P2565 |
Turbocharger Boost Control Position Sensor Circuit High |
-- Check the Turbocharger Control Module --. Refer to TURBOCHARGER CONTROL MODULE CHECKING . |
Sensor signal voltage > 4.85 V |
--- |
480 mSec. |
|
| P261A |
Coolant Pump "B" Control Circuit/Open |
-- Check the EGR Cooler Pump --. Refer to EGR COOLER PUMP CHECKING . |
- Open circuit Signal voltage < 5 V
- Functional voltage = 3.2 - 3.5 V
|
|
480 mSec. |
|
| P261C |
Coolant Pump "B" Control Circuit Low |
-- Check the EGR Cooler Pump --. Refer to EGR COOLER PUMP CHECKING . |
Signal voltage < 3 V |
|
480 mSec. |
|
| P261D |
Coolant Pump "B" Control Circuit High |
-- Check the EGR Cooler Pump --. Refer to EGR COOLER PUMP CHECKING . |
Signal voltage > 1.8 V |
|
480 mSec. |
|
| P2610 |
ECM/PCM Internal Engine Off Timer Performance |
-- Replace the Engine Control Module (ECM) -J623- Refer to the Repair information for procedure. |
Quantity time over threshold < 7.52 or > 8.48 Sec. |
Engine off |
24 Sec. in key Off position |
|
| P2632 |
Fuel Pump "B" Control Circuit Open |
-- Check the Auxiliary Fuel Pump -V393-. Refer to AUXILIARY FUEL PUMP CHECKING |
- Diagnostic signal from output stage > 4.5 V
|
Power stage = Off |
0.27 Sec. |
|
| P2633 |
Fuel Pump "B" Control Circuit Low |
-- Check the Auxiliary Fuel Pump -V393-. Refer to AUXILIARY FUEL PUMP CHECKING |
Grounded circuit diagnostic signal from output driver |
Power stage = Off |
480 mSec. |
|
| P2634 |
Fuel Pump "B" Control Circuit High |
-- Check the Auxiliary Fuel Pump -V393-. Refer to AUXILIARY FUEL PUMP CHECKING |
- Diagnostic signal from output stage > 2.7 A
|
Power stage = On |
2.27 Sec. |
|
| P310E |
Exhaust gas recirculation cooler bypass valve 2 Implausible signal |
-- Check the EGR Cooler Switch Over Valve --. Refer to EGR COOLER SWITCH OVER VALVE 1-2 CHECKING . |
Measured temperature < 0.8 |
- Engine speed = 1200 - 2500 rpm
- Delta engine speed = + -250 rpm
- Fuel quantity = 9 - 80 mg/stroke
- Delta fuel quantity = + -20 mg/stroke
- EGR valve > 0 - 80%
- Delta EGR = + -15%
- SCR temp > 150 °C
- EGR temp < 300 °C
|
11 Sec. |
|
| P3348 |
Activation turbocharger control unit bank 1 Electrical malfunction in circuit |
-- Check the Turbocharger Control Module --. Refer to TURBOCHARGER CONTROL MODULE CHECKING . |
- Diagnostic signal from power stage = 8 - 18 A
OR
- Diagnostic signal from power stage > 5 V or < 3.4 V
|
Power stage = On state |
480 mSec. |
|