Side Impact-Sensor Removal and Installation: Installation
Reference: SIDE IMPACT-SENSOR INSPECTION
CAUTION:
Proper operation of side impact-sensor requires that sensor is rigidly attached to specified position.
- Check that none of following faulty conditions exists.
- Bend, deformity or rust of under body.
- Foreign matter on mating surface of sensor.
- Install side impact-sensor (1) to side sill inner panel (2) and tighten side impact-sensor bolt (3) to specified torque.
Tightening torque
Side impact-sensor bolt (a): 9 N.m (0.9 kg-m, 6.5 lbf-ft)
- Connect side impact-sensor connector (4) by pushing connector till click is heard from it.
- Return the carpet, and install center pillar lower trim.
- Enable air bag system. Refer to ENABLING AIR BAG SYSTEM .
- Connect negative (-) cable at battery.