Diagnosis Procedure
WARNING: This page is about a different variant/trim than selected.
DIAGNOSIS PROCEDURE
| Step | Action | YES | NO |
|---|---|---|---|
| 1 | CHECK GROUND CONNECTIONS
OK or NG |
GO TO 2. | Repair or replace ground connections. |
| 2 | CHECK AIR FUEL RATIO (A/F) SENSOR 1 POWER SUPPLY CIRCUIT
Voltage: Battery voltage OK or NG |
GO TO 4. | GO TO 3. |
| 3 | DETECT MALFUNCTIONING PART Check the following.
|
Repair or replace harness or connectors. | |
| 4 | CHECK A/F SENSOR 1 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
Continuity should exist.
Continuity should not exist.
OK or NG |
GO TO 5. | Repair open circuit or short to ground or short to power in harness or connectors. |
| 5 | CHECK INTERMITTENT INCIDENT Perform [SERVICE INFORMATION FOR ELECTRICAL INCIDENT: INTERMITTENT INCIDENT ] OK or NG |
GO TO 6. | Repair or replace. |
| 6 | REPLACE A/F SENSOR 1 Replace malfunctioning A/F sensor 1. |
INSPECTION END |