LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Suzuki >> 2006 >> XL-7 Base, RWD, Automatic >> Repair and Diagnosis >> Transmission >> Automatic Trans >> Automatic Transmission >> Specifications >> Tightening Torque Specifications
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Tightening Torque Specifications

TIGHTENING TORQUE SPECIFICATIONS

Fastening part Tightening torque
N.m kgf-m lb-ft
A/T fluid drain plug 20 2.0 14.5
Manual selector assembly mounting bolt 18 1.8 13.5
Manual select cable end nut 19 1.9 14.0
Manual shift shaft nut 7 0.7 5.0
Transmission range sensor bolt 13 1.3 9.5
Manual select lever nut 13 1.3 9.5
Input shaft speed sensor bolt 5.5 0.55 4.0
Output shaft speed sensor bolt 5.5 0.55 4.0
Oil cooler pipe union bolt 25 2.5 18.0
Pipe clamp bolt 10 1.0 7.5
Torque converter mounting bolt 65 6.5 45.5
Transmission to engine bolt and nut 80 8.0 56.0
Drive plate bolt 69 6.9 48.3
Engine rear mounting bolt 55 5.5 38.5
Engine rear mounting member bolt 55 5.5 38.5
Stiffener mount bolt 55 5.5 38.5
Exhaust No.1 pipe to exhaust No.2 pipe nut 50 5.0 35.0
Exhaust muffler pipe to exhaust No.2 pipe nut 60 6.0 42.0
Front propeller shaft universal joint flange bolt 50 5.0 35.0
Rear propeller shaft universal joint flange bolt 60 6.0 42.0
Stabilizer bar mount bush bracket bolt 23 2.3 16.1
Oil pump body bolt 11 1.1 8.0
Oil pump bolt 21 2.1 15.0
Parking pawl bracket bolt 7.4 0.74 5.5
Valve body bolt 11 1.1 8.0
Transmission wire connector bolt 5.5 0.55 4.0
Transmission fluid temperature sensor clamp bolt 11 1.1 8.0
Transmission fluid temperature sensor clamp bolt 10 1.0 7.0
Oil strainer bolt 10 1.0 7.0
Oil pan bolt 4.5 0.45 3.5
Drain plug 20 2.0 14.5
Extension housing bolt 34 3.4 24.5
Transmission case adapter sub assembly bolt 34 3.4 24.5
Automatic transmission housing bolt 57 5.7 41.5
Automatic transmission housing bolt 34 3.4 24.5
Automatic transmission breather pipe bolt 5.5 0.55 4.0
Transmission speed sensor bolt 5.5 0.55 4.0

Reference: 

For the tightening torque of fastener not specified in this section, refer to FASTENER INFORMATION.