Receiver-Dryer Removal

  1. Disconnect the negative battery cable.
  2. Discharge and recover the refrigerant. Refer to Discharging, Adding Oil, Evacuating and Charging Procedures for A/C System .
  3. Remove the high-pressure pipe-to-receiver-dryer connecting block nut and remove the pipe from the receiver-dryer.
  4. Remove the receiver-dryer-to-condenser pipe nut.
    Fig 1: Identifying High-Pressure Pipe-To-Receiver-Dryer Connecting Block Nut & Receiver-Dryer-To-Condenser Pipe Nut
    G04720014Courtesy of SUZUKI OF AMERICA CORP.
  5. Loosen the bolt that secures the receiver-dryer band clamp.
    CAUTION: Hold the receiver-dryer-to-condenser pipe to support it so that the pipe is not damaged while being removed from the receiver-dryer.
  6. Remove the receiver-dryer by sliding it up and out of the band clamp.
  7. Cap all open connections to prevent contamination.
  8. Drain the oil from the receiver-dryer into a graduated container. Record the amount of oil drained.
  9. Discard the used oil.
    Fig 2: Identifying Receiver-Dryer Band Clamp & Bolt
    G04720015Courtesy of SUZUKI OF AMERICA CORP.