Ambient Air Temperature Sensor Installation
- Position the ambient air temperature sensor into its bracket.
- Install the retaining nut to the bracket.
Tighten:
Tighten the ambient air temperature retaining bracket nut to 6 N.m (53 lb-in.).
- Connect the electrical connector.
- Connect the negative battery cable.