Code 2 - Ambient Air Temperature Sensor Error
This code will set if the output of the ambient air temperature sensor indicates a probable short circuit or an open in the sensor or the associated wiring harness or a malfunction of the ATC controller.
STEP ACTION VALUE CHART
| Step | Action | Value(s) | Yes | No |
|---|---|---|---|---|
| 1 |
Is the resistance equal to the specified value at 20 - 25 °C (68 - 77 °F)? |
2,600 - 2,100 Ω | Go to Step 5 | Go to Step 2 |
| 2 |
Is there a problem with the wiring or the connector? |
- | Go to Step 3 | Go to Step 4 |
| 3 | Repair the problem found in the ambient air sensor wiring or the connector. Is the repair complete? |
- | System OK | - |
| 4 | Replace the ambient air sensor. Is the repair complete? |
- | System OK | - |
| 5 |
Is the voltage equal to the value specified? |
> 4 V | Go to Step 7 | Go to Step 6 |
| 6 |
Does this display indicate the continuing presence of a code 2 condition? |
- | Go to Step 8 | System OK |
| 7 |
Is the voltage equal to the value specified? |
< 4 V | Go to Step 8 | Go to Step 9 |
| 8 | Replace the ATC Controller. Is the repair complete? |
- | System OK | - |
| 9 |
Is the repair complete? |
- | System OK | - |