LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Volvo >> 2012 >> S80 T-6 >> Repair and Diagnosis >> Restraints >> Passive Restraints >> Closing Velocity Module (CVM), Forward Sensing Module (FSM), Keyless Vehicle Module (KVM) And Parking Assistance Module (PAM) - Specifications, Electrical/Electronic >> Forward Sensing Module (FSM) >> Signal Description (2012)
October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.

Signal Description (2012)

General 

All the values given below are between the respective terminal in column 1 and terminal #C1:10 in column 2 (power ground) unless otherwise stated in parenthesis after the table entry.

NOTE:

It is important to connect the breakout box and check the ground connections before starting to measure.

U= DC voltage in volts (V) UAC = AC voltage in volts (V)
Ubat = Battery voltage (V) f = Frequency in Hertz (Hz)
Ulow = Voltage approximately 0 V t = Time in seconds
PWM = Pulse width modulated signal as a %    
Fig 1: Connector Terminal Identification
GLL163444Courtesy of VOLVO CARS CORPORATION
SIGNAL TABLE

 
Connector C1
Breakout box terminal  Control module terminal  Signal type  Ignition off Active/Inactive  Ignition on Active/Inactive  Miscellaneous 
#1 #C1:1 Heating coil forward-aimed camera Ulow
/ Ulow
Ulow
/ Ubat
 
#2 #C1:2 LED 1 left Ulow
/ Ulow
Ulow
/ Ubat
Pulse width modulation (PWM) signal
#3 #C1:3 LED 2 middle Ulow
/Ulow
Ulow
/ Ubat
Pulse width modulation (PWM) signal
#4 #C1:4 LED 3 right Ulow
/ Ulow
Ulow
/ Ubat
Pulse width modulation (PWM) signal
#5 #C1:5 -      
#6 #C1:6 Communication CAN H
middle speed network
 
During communication the voltage is 1.5 - 2.5 V
 
#7 #C1:7 Communication CAN_L middle speed network During communication the voltage is 2.0 - 3.5 V  
#8 #C1:8 Local CAN bus FLR, high signal    
#9 #C1:9 Local CAN bus FLR, low signal    
#10 #C1:10 Power ground Ulow
/ Ulow
Ulow
/ Ulow
 
#11 #C1:11 15-feed Ulow
/ Ulow
Ulow
/ Ubat
 
#12 #C1:12 Power supply Ulow
/Ubat
Ulow
/Ubat
Via relay, interior lighting CEM.
#13 #C1:13 -      
#14 #C1:14 Ground, heating coil forward-aimed camera. Ulow
/ Ulow
Ulow
/ Ulow
 
#15 #C1:15 Indicator visual collision warning ground Ulow
/ U low
Ulow
/ Ulow
 
#16 #C1:16 -      
#17 #C1:17 -      
#18 #C1:18 Communication CAN_H, Sensor-CAN During communication the voltage is 2.0 - 3.5 V Latest used on S60(11-) and V60. Otherwise spare.
#19 #C1:19 Communication CAN_L, Sensor-CAN During communication the voltage is 1.5 - 2.5 V Latest used on S60(11-) and V60. Otherwise spare.
#20 #C1:20 -      
#21 #C1:21 -      
#22 #C1:22 -      
#23 #C1:23 -      
#24 #C1:24 -      
Fig 2: Connector Terminal Identification
GLL163446Courtesy of VOLVO CARS CORPORATION
Connector C:2
Control module terminal Signal type Ignition on Active/Inactive Miscellaneous
#C1:1 Forward facing camera, communication data 0-4 V  
#C2:2 Voltage supply, forward-aimed camera 4.4 V  
#C2:3 Ground, forward-aimed camera Ulow  
#C2:4 Forward-aimed camera, clock 0-4 V  
#C2:5 Video return signal    
#C2:6 Video signal 1.0 Vp-p  
#C2-S Cable protective ground 0 V The video cable has protective grounding to counteract interference.