Peripheral Camera System, Calibrating

Special tools and workshop equipment required 

Preparing 

Condition

Overview of the installed Calibration System VAS 721 001

GWWN98-000016Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.
  1. Left Calibration Field from the Calibration System :VAS 721 001 
  2. Front Peripheral Camera -R243-
  3. Right Calibration Field from the Calibration System :VAS 721 001 
  4. Right Peripheral Camera -R245-
  5. Rear Peripheral Camera -R246-
  6. Left Peripheral Camera -R244-

-- Check the camera images on the display unit.

-- Check the cameras, brackets, and retainers for damage, external influences, and secure fit.

-- Check and clear the DTC memory using the => Vehicle diagnostic tester.

-- Roll out the calibration fields to the left and right side, close to the vehicle.

GWWN98-000017Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.

Condition

-- Install the end strips at the front and rear of the calibration fields.

-- Align the calibration fields to the left and right side, close to the vehicle.

Condition

Calibrating

Condition

-- Perform the "Peripheral Camera System, Calibrating" function using the => Vehicle diagnostic tester. Refer to: Diagnostic Entries .