LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Volkswagen >> 2023 >> Tiguan SE R-Line Black, FWD >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> General, Technical Data Refrigerant R1234YF Servicing >> 00 General, Technical Data >> Technical And Physical Principles >> A/C Technology Basic Principles >> Refrigerant Pressure And Boiling Point
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Refrigerant Pressure And Boiling Point

The boiling point given in tables for a liquid is always referenced to an atmospheric pressure (1 bar (14.5 psi) absolute pressure). If the pressure acting on a fluid changes, its boiling point also changes.

NOTE:

Pressure is measured in different units: 1 MPa (mega Pascal) corresponds to 10 bar (145.04 psi) positive pressure or 145 psi. 1 bar (14.5 psi) absolute pressure corresponds to 0 bar (0 psi) positive pressure and thus to the ambient pressure (atmospheric pressure).

It is known that, for example, water boils at a lower temperature when the pressure is lower.

The vapor pressure curves for water and refrigerant R123yf show that, at constant pressure, reducing the temperature changes vapor to liquid (in the condenser) or that reducing the pressure causes the refrigerant to change from liquid to vapor (inside the evaporator).

Vapor pressure curve of water

Fig 1: Identifying Vapor Pressure Curve Of Water Graph
GWWN87-0523Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.

A -

Liquid

B -

Gaseous

C -

Vapor pressure curve of water

1 -

Pressure acting on liquid in bar (absolute)

2 -

Temperature in °C

Refrigerant R1234yf vapor pressure

Fig 2: Identifying Vapor Pressure Curve Of Refrigerant R134a Graph
GWWN87-0530Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.

A -

Liquid

B -

Gaseous

D -

Refrigerant R1234yf vapor pressure

1 -

Pressure acting on liquid in bar (absolute)

2 -

Temperature in °C

NOTE:

The vapor pressure curves of both refrigerant R1234yf and R134a is similar across a large temperature range. The pressure difference between both refrigerants in the temperature range of 0 °C to + 50 °C (32 °F to 122 °F) if for example only approximately 0.2 bar (2.9 psi) for this reason distinguishing the two refrigerants is not possible. Refer to REFRIGERANT VAPOR PRESSURE TABLE  and the appropriate service information . Differentiating is only possible using sensors that can analyze the chemical composition of the refrigerants. Refer to REFRIGERANT R1234YF ANALYSIS .