Possible Concerns

NOTE:

The A/C system is functioning correctly when the air flowing from the instrument panel vents has a temperature of 7 °C (44.6 °F) or lower.

Setting on Climatronic "LO".

Setting on A/C system "AC" on; "max" ; "cold".

NOTE:

With all complaints marked with *. Refer to PRESSURES, CHECKING .

From these, the following complaints may also occur:

The A/C Compressor Makes Noises

-- Re-tighten compressor securing bolts and compressor bracket using a torque wrench.

-- Check routing of refrigerant lines; they must not touch other components and must not be subject to strain (align if necessary).

Noise (Refrigerant Hammer) Occurring Immediately after Switching on Air Conditioner and/or When Cornering or Braking:

-- Discharge, evacuate and charge refrigerant circuit (too much refrigerant in circuit).

NOTE:

Too much refrigerant oil in the circuit could also cause this problem. This could occur if the amount of refrigerant oil was not adjusted when replacing the A/C compressor. If this occurs, flush the refrigerant circuit with refrigerant R134a. Refer to REFRIGERANT CIRCUIT, FLUSHING WITH R134A REFRIGERANT .

Drain the refrigerant from the A/C compressor. To facilitate this, the ribbed belt pulley or A/C clutch plate on the A/C compressor should be rotated by hand. Then the entire quantity of refrigerant oil specified by the a Vehicle-Specific Service Information should be added to the refrigerant circuit (50 grams directly in the A/C compressor).

Water Sprays out of Vents (in Dash Panel or Footwell) Although Air Conditioning System Is Otherwise Functioning Properly:

-- Check proper routing of condensate drain; it must not be crushed or kinked.

-- Check condensation drain valve, it must not be clogged by wax or underbody sealant and must open and close properly.

-- Check plenum chamber cover; it must not be damaged and must be properly installed (to stop water running into evaporator).

-- Check water drains in plenum chamber; they must not be blocked (e.g. by leaves).