01-22-04 - Unnecessary Replacement Of Engine/Motor Control Module -J623- (GROUP 01, NO. 22-04)
Publication date: 2024-12-16Reference number: GROUP 01, NO. 22-04
Supersedes refnos: 2067010/1, 2067010/2, 2067010/3, 2067010/4, 2067010/5
01-22-04 - UNNECESSARY REPLACEMENT OF ENGINE/MOTOR CONTROL MODULE -J623-
TECHNICAL SERVICE BULLETIN
| VOLKSWAGEN: | 2021-2024 Tiguan |
| GROUP: | 01 - On-Board Diagnostic |
CONDITION
| Model(s) | Year | Eng. Code | Trans. Code | VIN Range From | VIN Range To |
|---|---|---|---|---|---|
| Tiguan | 2021-2024 | All | All | All | All |
| Instance Number | Published Date | Version Number | Reason For Update |
|---|---|---|---|
| 2067010/5 | 12/16/2022 | 01-22-04 | Update to GFF labor operation number and include battery charge labor operation. |
| 2067010/4 | 03/11/2022 | 01-22-04 | Update to include additional model year applicability. |
| 2067010/2 | 07/26/2022 | 01-22-04 | Update to labor operation time units in warranty table. |
| 2067010/1 | 05/11/2022 | 01-22-04 | Original publication. |
Unnecessary replacement of Engine/Motor Control Module -J623 - (ECM) due to faulty starter motor.
Faults stored in Engine/Motor Control Module -J623 - may lead technician to incorrect repair of the vehicle.
The following group or more of fault codes must be stored in the Engine/Motor Control Module -J623 -(ECM) Fault Memory in order for this technical bulletin to apply.
| DTC | Description |
|---|---|
| U000100 | High Speed CAN Communication Bus |
| P06E9 | Engine Starter Performance |
| P06EF | Engine Restart Performance |
| U041600 | Invalid Data Received from Vehicle Dynamics Control Module |
| P060C (Symptom code 20359) | Internal Control Module Main Processor Performance |
| P060C (Symptom code 31586) | Internal Control Module Main Processor Performance |
| P2532 | Ignition Switch Run Position Circuit High |
| P0606 | ECM/PCM Processor |
| P1624 | Requirement - malfunction lamp on active |
TECHNICAL BACKGROUND
Contamination inside the starter motor may cause an intermittent open circuit of the internal contacts.
PRODUCTION SOLUTION
Final production counter measure pending.
SERVICE
DO NOT replace the ECM for this concern. ECM faults P060C and P0606 are stored in the ECM as a result of the starter motor failing to start the vehicle after a start/stop event.
If the above group of faults are stored in the ECM, replace the starter motor, clear the faults, and test drive the vehicle. If no faults return, no further work is required.
If any faults do return, additional diagnosis is needed.
WARRANTY
| To determine if this procedure is covered under Warranty, always refer to the Warranty Policies and Procedures Manual (1) | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Model(s) | Year(s) | Eng. Code(s) | Trans. Code(s) | VIN Range From | VIN Range To | ||||||||
| Tiguan | 2021-2024 | All | All | All | All | ||||||||
| SAGA Coding | |||||||||||||
| Claim Type: | Use applicable Claim Type (1) | ||||||||||||
| Service Number: | Damage Code | HST | Damage Location (Depends on Service No.) | ||||||||||
| 2760 | 0040 | - | - | ||||||||||
| Parts Manufacturer | Tiguan | 3ME(2) | |||||||||||
| Labor Operation (3) : Battery charge | 27068950 = see Elsa for latest time units. | ||||||||||||
| Labor Operation (3) : Remove and reinstall starter motor | 27601973 = see Elsa for latest time units. | ||||||||||||
| Labor Operation (3) : Remove and reinstall air cleaner | 24251970 = see Elsa for latest time units. | ||||||||||||
| Causal Part: Select Labor operation | 27601973 | ||||||||||||
| Diagnostic Time (4) | |||||||||||||
| GFF/Guided Functions | 01500060 = Time stated on GFF log | Yes | |||||||||||
| Road Test | 01210004 = see Elsa for latest time units. | Yes | |||||||||||
| Technical Diagnosis | 01320000 = 00 TU max. | No | |||||||||||
| Claim Comment: Input "As per Technical Bulletin 2067010" in comment section of Warranty Claim. | |||||||||||||
|
|||||||||||||
REQUIRED PARTS AND TOOLS
| Part No: | Part Description | Quantity | ||
|---|---|---|---|---|
| 02M911022F/FX(1) | Starter Motor | 1 | ||
|
||||
| Tool Description | Tool No: |
|---|---|
| Midtronics Battery Maintainer | MYRMSP0702 |
| VAS Diagnostic Tool | VAS 6150/X & VAS 6160/X with ODIS Service with: current online updates |
ADDITIONAL INFORMATION
All part and service references provided in this Technical Bulletin are subject to change and/or removal.
Always check with your Parts Dept. and Repair Manuals for the latest information.