Overview - Windshield
- Windshield
- Removing and Installing. Refer to WINDSHIELD, REMOVING AND INSTALLING .
- Spacer
- Quantity: 5
- PUR Adhesive Sealant
- Adhesive bead diameter including precoating, residual material on the window glass and window glass flange
Dimension -a- = 6.5 mm ± 0.5 mm
Dimension -b- = 10.0 mm ± 1.0 mm
- Beginning and end of the adhesive bead at the -arrow-
- Minimum Curing Time. Refer to MINIMUM CURING TIMES FOR BONDED WINDOWS .
- Adhesive bead diameter including precoating, residual material on the window glass and window glass flange
- Body Flange
- Prepare the body flange for installation. Refer to BODY FLANGE, PREPARING FOR INSTALLATION .
- Gap dimension between the windshield and roof
- Refer to BODY FRONT
- Spacer
- Quantity: 2 :443 845 631 A
- Insert when attaching the windshield during the minimum curing time -direction of the arrow-
- Remove when installing the plenum chamber cover
- Retainer
- Windshield component
- Plenum Chamber Cover
- Removing and Installing. Refer to PLENUM CHAMBER COVER, REMOVING AND INSTALLING .