Condenser, Removing And Installing: Installing
Install in the reverse order of removal while noting the following:
-- Replace the seals. Refer to the Parts Information.
-- If the condenser is replaced, 10 % of the total capacity of refrigerant oil must be filled in the installed A/C compressor in the refrigerant circuit. Refer to TECHNICAL DATA .
-- Coat the new seals with refrigerant oil before installing the refrigerant line.
There is a risk of damaging the A/C compressor if the refrigerant circuit is empty.
- Never start the engine with the refrigerant circuit empty.
Vehicles with Refrigerant R134a
-- Fill the refrigerant circuit. Refer to Working with A/C Service Station .
-- Perform the leak test on the refrigerant circuit line connections that were closed again. Refer to Refrigerant Circuit, Detecting Leaks .
Vehicles with Refrigerant R1234yf
-- Charge the refrigerant circuit. Refer to Working with A/C Service Station (1 Of 2) / Working with A/C Service Station (2 Of 2) .
-- Perform the leak test on the closed line connections of the refrigerant circuit. Refer to LEAKS, FINDING .