LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Volkswagen >> 2023 >> GTI SE, Automatic DCT Trans >> Repair and Diagnosis (Single Page) >> Engine Performance >> System >> Generic Scan Tool (Engine & Transmission DTC Tables) >> St Generic Scan Tool >> Diagnosis And Testing >> Transmission DTC Tables >> Transmission Control Module --, DQ381-7A/F (7 SPEED) 0GC (2021, 2022 MY)
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Transmission Control Module --, DQ381-7A/F (7 SPEED) 0GC (2021, 2022 MY)

Component / System Fault Code Monitor Strategy Malfunction Criteria Threshold Value Secondary Parameters Enable Conditions Monitor Time Length Frequency of Checks MIL Illum.
                   
Gear Shift Module 1 - 3 P2832 - Shift Fork "A" Position Circuit Range/Performance signal range check Duty-Cycle Position sensor >92.5 % < 7.5 % Sensor supply voltage between 4.5 - 5.5 V 2 s continuous 2 DCY
Gear Shift Module 4 - 6 P2841 - Shift Fork "D" Position Circuit Range/Performance signal range check Duty-Cycle Position sensor >92.5 % < 7.5 % Sensor supply voltage between 4.5 - 5.5 V 2 s continuous 2 DCY
Gear Shift Module 5 - 7 P283C - Shift Fork "C" Position Circuit Range/Performance signal range check Duty-Cycle Position sensor >92.5 % < 7.5 % Sensor supply voltage between 4.5 - 5.5 V 2 s continuous 2 DCY
Gear Shift Module 2 - R P2837 - Shift Fork "B" Position Circuit Range/Performance signal range check Duty-Cycle Position sensor >92.5 % < 7.5 % Sensor supply voltage between 4.5 - 5.5 V 2 s continuous 2 DCY
Gear Shift Module 1 - 3 P2831 - Shift Fork "A" Position Circuit signal range check no signal > 1 [s]     2 s continuous 2 DCY
Gear Shift Module 4 - 6 P2840 - Shift Fork "D" Position Circuit signal range check no signal > 1 [s]     2 s continuous 2 DCY
Gear Shift Module 5 - 7 P283B - Shift Fork "C" Position Circuit signal range check no signal > 1 [s]     2 s continuous 2 DCY
Gear Shift Module 2 - R P2836 - Shift Fork "B" Position Circuit signal range check no signal > 1 [s]     2 s continuous 2 DCY
Gear Shift Module 1 - 3 P2832 - Shift Fork "A" Position Circuit Range/Performance signal range check time of oscillation < 0.9 [ms] > 1.1 [ms] Sensor supply voltage between 4.5 - 5.5 V 2 s continuous 2 DCY
Gear Shift Module 4 - 6 P2841 - Shift Fork "D" Position Circuit Range/Performance signal range check time of oscillation < 0.9 [ms] > 1.1 [ms] Sensor supply voltage between 4.5 - 5.5 V 2 s continuous 2 DCY
Gear Shift Module 5 - 7 P283C - Shift Fork "C" Position Circuit Range/Performance signal range check time of oscillation < 0.9 [ms] > 1.1 [ms] Sensor supply voltage between 4.5 - 5.5 V 2 s continuous 2 DCY
Gear Shift Module 2 - R P2837 - Shift Fork "B" Position Circuit Range/Performance signal range check time of oscillation < 0.9 [ms] > 1.1 [ms] Sensor supply voltage between 4.5 - 5.5 V 2 s continuous 2 DCY
Speed Sensor Shaft 1 P0718 - Input/Turbine Shaft Speed Sensor "A" Circuit Intermittent rationality check no signal > 1 [s] Ignition on 2 s continuous 2 DCY
Speed Sensor Shaft 2 P2768 - Input/Turbine Shaft Speed Sensor "B" Circuit Intermittent rationality check no signal > 1 [s] Ignition on 2 s continuous 2 DCY
Speed Sensor Shaft 1 P0501 - Vehicle Speed Sensor "A" Circuit Range/Performance rationality check difference between measured and calculated output speed for shaft 1 and difference between output shaft speed 1 and shaft 2 > 150 rpm and > 150 rpm Input shaft speeds for shafts 1 and 2 > 100 rpm 2 s continuous 2 DCY
Speed Sensor Shaft 2 P2159 - Vehicle Speed Sensor "B" Circuit Range/Performance rationality check difference between measured and calculated output speed for shaft 2 and difference between output shaft speed 1 and shaft 2 > 150 rpm and > 150 rpm Input shaft speeds for shafts 1 and 2 > 100 rpm 2 s continuous 2 DCY
Speed Sensor Shaft 1 and Shaft 2 P2162 - Vehicle Speed Sensor "A"/"B" Correlation rationality check difference between output shaft speeds and input speeds shafts 1 and 2 > 150 rpm Input shaft speeds for shafts 1 and 2 and Engaged gear position is not > 100 rpm and Neutral 2 s continuous 2 DCY
TCM Temperature Sensor P0666 - Control Module Internal Temperature Sensor "A" Circuit circuit continuity check TCM Temperature Sensor self check TCM Temperature Sensor failed invalid state Ignition TCM Temperature Sensor Initialization on finished 2 s continuous 2 DCY
TCM Temperature Sensor P0666 - Control Module Internal Temperature Sensor "A" Circuit circuit continuity check TCM Temperature Sensor at and actual chip temperature or actual chip temperature -0.03125 [°C] and < -24 [°C] or > 24 [°C] Ignition TCM Temperature Sensor Initialization on finished 2 s continuous 2 DCY

Table continues below.

Component / System Fault Code Monitor Strategy Malfunction Criteria Threshold Value Secondary Parameters Enable Conditions Monitor Time Length Frequency of Checks MIL Illum.
TCM Temperature Sensor P0667 - Control Module Internal Temperature Sensor "A" Range/Performance rationality check difference between TCM Temperature Sensor and internal chip temperature 26 > x > -26 [°C] Ignition TCM Temperature Sensor Initialization on finished 2 s continuous 2 DCY
TCM Temperature Sensor P0667 - Control Module Internal Temperature Sensor "A" Range/Performance rationality check difference between actual TCM Temperature Sensor and filtered temperature > 8 [°C] Ignition on 2 s continuous 2 DCY
TCM Temperature Sensor P0713 - Transmission Fluid Temperature Sensor "A" Circuit High rationality check short circuit to high > 4.7 [V] power supply voltage 6-18 V 2 s continuous 2 DCY
TCM Temperature Sensor P0712 - Transmission Fluid Temperature Sensor "A" Circuit Low rationality check short circuit to ground < 0.16 [V] power supply voltage 6-18 V 2 s continuous 2 DCY
TCM Temperature Sensor P0711 - Transmission Fluid Temperature Sensor "A" Circuit Range/Performance rationality check actual ATF temperature > 170 [°C] < -50 [°C] power supply voltage 6-18 V 2 s continuous 2 DCY
TCM Temperature Sensor P0711 - Transmission Fluid Temperature Sensor "A" Circuit Range/Performance circuit continuity check difference between actual ATF temperature and filtered temperature > 15° C power supply voltage 6-18 V 2 s continuous 2 DCY
ATF Pump Speed Sensor P0C2D - Electric/Auxiliary Transmission Fluid Pump Control Module Feedback Signal Low signal range check sensor output voltage < 0.25 V sensor supply voltage 4.5-5.5 V 2 s continuous 2 DCY
ATF Pump Speed Sensor P0C2E - Electric/Auxiliary Transmission Fluid Pump Control Module Feedback Signal High signal range check sensor output voltage > 4.5 V sensor supply voltage 4.5-5.5 V 2 s continuous 2 DCY
ATF Pump Speed Sensor P0C2C - Electric/Auxiliary Transmission Fluid Pump Control Module Feedback Signal Range/Performance rationality check sensor output sin A 2 +cos A 2 > 0.8 or < 1.2 sensor supply voltage 4.5-5.5 V 2 s continuous 2 DCY
Temperature Sensor P0711 - Transmission Fluid Temperature Sensor "A" Circuit Range/Performance rationality check difference between ATF temperature and TCU temperature > 20° C   too high deviation between temperature measured at the TCU PCB and temperature measured in ATF oil after a longer term of transmission cool down. 0 s once/DCY 2 DCY
Supply Voltage Monitoring Stage 3 P06D5 - Sensor Reference Voltage "E" Circuit Range/Performance Signal range check Internal sensor supply voltage > 5.5 V or < 4.5     2 s continuous 2 DCY
(Electrical) ATF Pump P0C2A - Electric/Auxiliary Transmission Fluid Pump "A" Motor Stalled functional check current ATF pump speed < and set current for ATF pump control 300 rpm and 30-50 A ATF pump governor and target ATF-engine speed > enabled and 300 rpm 2 s continuous 2 DCY
(Electrical) ATF Pump P0B0D - Electric/Auxiliary Transmission Fluid Pump Motor Control Module signal range check Difference between actual and commanded ATF pump speed > 500 rpm Calibration not aktiv 2 s continuous 2 DCY
(Electrical) ATF Pump P0C28 - Electric/Auxiliary Transmission Fluid Pump "A" Motor Current High functional check ATF pump over current protection active     2 s continuous 2 DCY
(Electrical) ATF Pump Control Module P0C29 - Electric/Auxiliary Transmission Fluid Pump "A" Driver Circuit Performance circuit continuity check electrical failure in power amplifier (Endtsufe)       2 s continuous 2 DCY
(Electrical) ATF Pump Control Module P0C29 - Electric/Auxiliary Transmission Fluid Pump "A" Driver Circuit Performance circuit continuity check driver error       2 s continuous 2 DCY
(Electrical) ATF Pump Control Module P0C29 - Electric/Auxiliary Transmission Fluid Pump "A" Driver Circuit Performance circuit continuity check overload ATF pump       2 s continuous 2 DCY
Solenoid for gear 1-3 P0750 - Shift Solenoid "A" circuit continuity check Difference between set current and measured current. > 100 mA     2 s continuous 2 DCY
Solenoid for gear 4-6 P0765 - Shift Solenoid "D" circuit continuity check Difference between set current and measured current. > 100 mA     2 s continuous 2 DCY

Table continues below.

Component / System Fault Code Monitor Strategy Malfunction Criteria Threshold Value Secondary Parameters Enable Conditions Monitor Time Length Frequency of Checks MIL Illum.
Solenoid for gear 5-7 P0760 - Shift Solenoid "C" circuit continuity check Difference between set current and measured current. > 100 mA     2 s continuous 2 DCY
Solenoid for gear 2-R P0755 - Shift Solenoid "B" circuit continuity check Difference between set current and measured current. > 100 mA     2 s continuous 2 DCY
Solenoid for clutch 1 P0745 - Pressure Control Solenoid "A" circuit continuity check Difference between set current and measured current. > 100 mA     2 s continuous 2 DCY
Solenoid for clutch 2 P0775 - Pressure Control Solenoid "B" circuit continuity check Difference between set current and measured current. > 100 mA     2 s continuous 2 DCY
Solenoid for main pressure P0795 - Pressure Control Solenoid "C" circuit continuity check Difference between set current and measured current. > 100 mA     2 s continuous 2 DCY
Solenoid for cooling P0770 - Shift Solenoid "E" circuit continuity check Difference between set current and measured current. > 100 mA     2 s continuous 2 DCY
Solenoid for over pressure reduction P2706 - Shift Solenoid "F" circuit continuity check Difference between set current and measured current. > 100 mA     2 s continuous 2 DCY
Gear Actuator 1-3 P284D - Shift Fork "A" Un-requested Movement functional check Loaded gear leaves the engage-position > 3 [mm] Gear actuator 1-3 nominal state is engaged 2 s continuous 2 DCY
Gear Actuator 4-6 P2850 - Shift Fork "D" Un-requested Movement functional check Loaded gear leaves the engage-position > 3 [mm] Gear actuator 4-6 nominal state is engaged 2 s continuous 2 DCY
Gear Actuator 5-7 P284F - Shift Fork "C" Un-requested Movement functional check Loaded gear leaves the engage-position > 3 [mm] Gear actuator 5-7 nominal state is engaged 2 s continuous 2 DCY
Gear Actuator 2-R P284E - Shift Fork "B" Un-requested Movement functional check Loaded gear leaves the engage-position > 3 [mm] Gear actuator 2-R nominal state is engaged 2 s continuous 2 DCY
Gear Actuator 1-3 P187A - Gear Selector 1 Engaging Process Not Successful functional check Time out in gear actuator state after synchronization > 1 [s] Gear actuator 1-3 nominal state is after synchronization 2 s continuous 2 DCY
Gear Actuator 4-6 P187D - Gear Selector 4 Engaging Process Not Successful functional check Time out in gear actuator state after synchronization > 1 [s] Gear actuator 4-6 nominal state is after synchronization 2 s continuous 2 DCY
Gear Actuator 5-7 P187C - Gear Selector 3 Engaging Process Not Successful functional check Time out in gear actuator state after synchronization > 1 [s] Gear actuator 5-7 nominal state is after synchronization 2 s continuous 2 DCY
Gear Actuator 2-R P187B - Gear Selector 2 Engaging Process Not Successful functional check Time out in gear actuator state after synchronization > 1 [s] Gear actuator 2-R nominal state is after synchronization 2 s continuous 2 DCY
Gear Actuator 1-3 P187A - Gear Selector 1 Engaging Process Not Successful functional check Time out in gear actuator state Unlatched > 1 [s] Gear actuator 1-3 nominal state is Unlatched 2 s continuous 2 DCY
Gear Actuator 4-6 P187D - Gear Selector 4 Engaging Process Not Successful functional check Time out in gear actuator state Unlatched > 1 [s] Gear actuator 4-6 nominal state is Unlatched 2 s continuous 2 DCY
Gear Actuator 5-7 P187C - Gear Selector 3 Engaging Process Not Successful functional check Time out in gear actuator state Unlatched > 1 [s] Gear actuator 5-7 nominal state is Unlatched 2 s continuous 2 DCY
Gear Actuator 2-R P187B - Gear Selector 2 Engaging Process Not Successful functional check Time out in gear actuator state Unlatched > 1 [s] Gear actuator 2-R nominal state is Unlatched 2 s continuous 2 DCY
Gear Actuator 1-3 P187A - Gear Selector 1 Engaging Process Not Successful functional check Time out in gear actuator state Engage > 1 [s] Gear actuator 1-3 nominal state is Engage 2 s continuous 2 DCY
Gear Actuator 4-6 P187D - Gear Selector 4 Engaging Process Not Successful functional check Time out in gear actuator state Engage > 1 [s] Gear actuator 4-6 nominal state is Engage 2 s continuous 2 DCY
Gear Actuator 5-7 P187C - Gear Selector 3 Engaging Process Not Successful functional check Time out in gear actuator state Engage > 1 [s] Gear actuator 5-7 nominal state is Engage 2 s continuous 2 DCY
Gear Actuator 2-R P187B - Gear Selector 2 Engaging Process Not Successful functional check Time out in gear actuator state Engage > 1 [s] Gear actuator 2-R nominal state is Engage 2 s continuous 2 DCY
Gear Actuator 1-3 P2845 - Shift Fork "A" Position Sensor Incorrect Neutral Position Indicated functional check Gear actuator 1-3 leaves the neutral-position > 3 [mm] Gear actuator 1-3 nominal state is Neutral 2 s continuous 2 DCY

Table continues below.

Component / System Fault Code Monitor Strategy Malfunction Criteria Threshold Value Secondary Parameters Enable Conditions Monitor Time Length Frequency of Checks MIL Illum.
Gear Actuator 4-6 P2848 - Shift Fork "D" Position Sensor Incorrect Neutral Position Indicated functional check Gear actuator 4-6 leaves the neutral-position > 3 [mm] Gear actuator 4-6 nominal state is Neutral 2 s continuous 2 DCY
Gear Actuator 5-7 P2847 - Shift Fork "C" Position Sensor Incorrect Neutral Position Indicated functional check Gear actuator 5-7 leaves the neutral-position > 3 [mm] Gear actuator 5-7 nominal state is Neutral 2 s continuous 2 DCY
Gear Actuator 2-R P2846 - Shift Fork "B" Position Sensor Incorrect Neutral Position Indicated functional check Gear actuator 2-R leaves the neutral-position > 3 [mm] Gear actuator 2-R nominal state is Neutral 2 s continuous 2 DCY
Gear Actuator 1-3 P284D - Shift Fork "A" Un-requested Movement functional check Gear actuator 1-3 leaves the engage position > 1 [s] Gear actuator 1-3 nominal state is Engaged 2 s continuous 2 DCY
Gear Actuator 4-6 P2850 - Shift Fork "D" Un-requested Movement functional check Gear actuator 4-6 leaves the engage position > 1 [s] Gear actuator 4-6 nominal state is Engaged 2 s continuous 2 DCY
Gear Actuator 5-7 P284F - Shift Fork "C" Un-requested Movement functional check Gear actuator 5-7 leaves the engage position > 1 [s] Gear actuator 5-7 nominal state is Engaged 2 s continuous 2 DCY
Gear Actuator 2-R P284E - Shift Fork "B" Un-requested Movement functional check Gear actuator 2-R leaves the engage position > 1 [s] Gear actuator 2-R nominal state is Engaged 2 s continuous 2 DCY
Gear Actuator 1-3 P2849 - Shift Fork "A" Stuck functional check Time out in gear actuator state Disengage > 2 [s] Gear actuator 1-3 nominal state is Disengage 2 s continuous 2 DCY
Gear Actuator 4-6 P284C - Shift Fork "D" Stuck functional check Time out in gear actuator state Disengage > 2 [s] Gear actuator 4-6 nominal state is Disengage 2 s continuous 2 DCY
Gear Actuator 5-7 P284B - Shift Fork "C" Stuck functional check Time out in gear actuator state Disengage > 2 [s] Gear actuator 5-7 nominal state is Disengage 2 s continuous 2 DCY
Gear Actuator 2-R P284A - Shift Fork "B" Stuck functional check Time out in gear actuator state Disengage > 2 [s] Gear actuator 2-R nominal state is Disengage 2 s continuous 2 DCY
Gear Actuator 1-3 P187A - Gear Selector 1 Engaging Process Not Successful functional check Time out in gear actuator state Synchronize > 2 [s] Gear actuator 1-3 nominal state is Synchronize 2 s continuous 2 DCY
Gear Actuator 4-6 P187D - Gear Selector 4 Engaging Process Not Successful functional check Time out in gear actuator state Synchronize > 2 [s] Gear actuator 4-6 nominal state is Synchronize 2 s continuous 2 DCY
Gear Actuator 5-7 P187C - Gear Selector 3 Engaging Process Not Successful functional check Time out in gear actuator state Synchronize > 2 [s] Gear actuator 5-7 nominal state is Synchronize 2 s continuous 2 DCY
Gear Actuator 2-R P187B - Gear Selector 2 Engaging Process Not Successful functional check Time out in gear actuator state Synchronize > 2 [s] Gear actuator 2-R nominal state is Synchronize 2 s continuous 2 DCY
Drive-Off Clutch 1 P0811 - Excessive Clutch "A" Slippage rationality check Clutch slippage was detected > 150 rpm Clutch state is Drive 2 s continuous 2 DCY
Drive-Off Clutch 2 P081E - Excessive Clutch "B" Slippage rationality check Clutch slippage was detected > 150 rpm Clutch state is Drive 2 s continuous 2 DCY
Speed Sensor Shaft 1 P0716 - Input/Turbine Shaft Speed Sensor "A" Circuit Range/Performance signal range check Input shaft speed for shaft 1 > 12000 rpm     2 s continuous 2 DCY
Speed Sensor Shaft 2 P2766 - Input/Turbine Shaft Speed Sensor "B" Circuit Range/Performance signal range check Input shaft speed for shaft 2 > 12000 rpm     2 s continuous 2 DCY
Solenoid for gear 1-3 P0753 - Shift Solenoid "A" Electrical circuit continuity check internal voltage failure     2 s continuous 2 DCY
Solenoid for gear 5-7 P0763 - Shift Solenoid "C" Electrical circuit continuity check internal voltage failure     2 s continuous 2 DCY
Solenoid for clutch 1 P0748 - Pressure Control Solenoid "A" Electrical circuit continuity check internal voltage failure     2 s continuous 2 DCY
Solenoid for over pressure reduction P2709 - Shift Solenoid "F" Electrical circuit continuity check internal voltage failure     2 s continuous 2 DCY
Solenoid for gear 2-R P0758 - Shift Solenoid "B" Electrical circuit continuity check internal voltage failure     2 s continuous 2 DCY
Solenoid for gear 4-6 P0768 - Shift Solenoid "D" Electrical circuit continuity check internal voltage failure     2 s continuous 2 DCY
Solenoid for clutch 2 P0778 - Pressure Control Solenoid "B" Electrical circuit continuity check internal voltage failure     2 s continuous 2 DCY
Solenoid for main pressure P0798 - Pressure Control Solenoid "C" Electrical circuit continuity check internal voltage failure     2 s continuous 2 DCY
Solenoid for cooling P0773 - Shift Solenoid "E" Electrical circuit continuity check internal voltage failure     2 s continuous 2 DCY

Table continues below.

Component / System Fault Code Monitor Strategy Malfunction Criteria Threshold Value Secondary Parameters Enable Conditions Monitor Time Length Frequency of Checks MIL Illum.
TCM internal driver A P0702 - Transmission Control System Electrical circuit continuity check internal voltage failure     2 s continuous 2 DCY
TCM internal driver B P0702 - Transmission Control System Electrical circuit continuity check internal voltage failure     2 s continuous 2 DCY
TCM internal driver C P0702 - Transmission Control System Electrical circuit continuity check internal voltage failure     2 s continuous 2 DCY
TCM P0700 - Transmission Control System (MIL Request) functional check CPU permanent shutdown of all actors active     2 s continuous 2 DCY
TCM P062F - Internal Control Module EEPROM Error rationality check comparison of EEProm date - both copies invalid when reading a data block active 2 s continuous 2 DCY
TCM P062F - Internal Control Module EEPROM Error memory check comparison of stored value - both copies invalid when reading a data block active 2 s continuous 2 DCY
TCM P062F - Internal Control Module EEPROM Error memory check write ability check faulty     2 s continuous 2 DCY
TCM P0701 - Transmission Control System Range/Performance function check repeated malfunctions at SOPC       2 s one time during startup 2 DCY
Supply Voltage Monitoring Stage 1 P0560 - System Voltage Signal range check Internal sensor supply voltage > 5.5 V or < 4.5     2 s continuous 2 DCY
Supply voltage Monitoring Stage 2 P0560 - System Voltage Signal range check Internal sensor supply voltage > 5.5 V or < 4.5     2 s continuous 2 DCY
TCM internal driver A P06A6 - Sensor Reference Voltage "A" Circuit Range/Performance circuit continuity check voltage 2 [V]     2 s continuous 2 DCY
TCM internal driver B P06A7 - Sensor Reference Voltage "B" Circuit Range/Performance circuit continuity check voltage 2 [V]     2 s continuous 2 DCY
TCM internal driver C P06A8 - Sensor Reference Voltage "C" Circuit Range/Performance circuit continuity check voltage 2 [V]     2 s continuous 2 DCY
Supply Voltage Monitoring P06A9 - Sensor Reference Voltage "D" Circuit Range/Performance signal range check Internal sensor supply voltage < 9 V     2 s continuous 2 DCY
Supply Voltage Monitoring P0562 - System Voltage Low signal range check Voltage and one of the following monitors is in protective function P0750, P0765, P0760, P0755, P0745, P0775, P0795, P0770, P2706 < 8 V     5 s continuous 2 DCY
(Electrical) ATF Pump P0B0A - Electric/Auxiliary Transmission Fluid Pump "A" Motor Supply Voltage Circuit Low signal range check Voltage and P0B0D is in protective function < 10 [V]     2 s continuous 2 DCY
Supply Voltage Monitoring P0563 - System Voltage High signal range check Voltage > 18 V     2 s continuous 2 DCY
FlexRay U0151 - Lost Communication With Restraints Control Module communication check Lost Communication With Restraints Control Module   Ignition on 2 s continuous 2 DCY
Solenoid for clutch 1 P0747 - Pressure Control Solenoid "A" Stuck On functional check The actual pressure on clutch K1 is different to the requested pressure on clutch K1       2 s continuous 2 DCY
Solenoid for clutch 2 P0777 - Pressure Control Solenoid "B" Stuck On functional check The actual pressure on clutch K2 is different to the requested pressure on the clutch K2       2 s continuous 2 DCY
ECU P060B - Internal Control Module A/D Processing Performance rationality check repeated implausible sensor signal       2 s continuous 2 DCY
TCM Safety monitor P0607 - Control Module Performance function check traction in the opposite driving direction       2 s continuous 2 DCY
TCM Safety monitor P0607 - Control Module Performance function check too low gear selected and clutch closed       2 s continuous 2 DCY
TCM Safety monitor P0607 - Control Module Performance function check too low gear selected       2 s continuous 2 DCY

Table continues below.

Component / System Fault Code Monitor Strategy Malfunction Criteria Threshold Value Secondary Parameters Enable Conditions Monitor Time Length Frequency of Checks MIL Illum.
ECU P2C83 - Cold Start Shift Time Too Short functional check Engine minimum speed requirement, sent from ECU to TCU during cold start, is not satisfied     There is no transmission malfunction that reduce the available gears, the gear selection is D or S and a minimum speed requirement caused by CSERS is sent to the TCU   once/DCY 2 DCY
ECU P0895 - Shift Time Too Short functional check Engine minimum speed requirement, sent from ECU to TCU because of an OBD relevant measure (not CSERS), is not satisfied     There is no transmission malfunction that reduce the available gears, the gear selection is D or S and a minimum speed requirement caused by an OBD relevant measure (not CSERS) is sent to the TCU   multiple/DCY 2 DCY
TCM Safety monitor P0607 - Control Module Performance function check two gears on one shaft       2 s continuous 2 DCY
TCM Safety monitor P0607 - Control Module Performance function check both clutches closed       2 s continuous 2 DCY
TCM Safety monitor P0607 - Control Module Performance function check incorrect clutch actuation       2 s continuous 2 DCY
Flexray U0100 - Lost Communication With ECM/PCM "A" communication check Engine Control Module no signal Ignition on 2 s continuous 2 DCY
Flexray U0121 - Lost Communication With Anti-Lock Brake System (ABS) Control Module "A" communication check Anti-Lock Brake System no signal Ignition on 2 s continuous 2 DCY
Flexray U0401 - Invalid Data Received From ECM/PCM "A" communication check invalid data received from Engine Control Module   Ignition on 2 s continuous 2 DCY
Flexray U0415 - Invalid Data Received From Anti-Lock Brake System (ABS) Control Module "A" communication check invalid data received from Anti-Lock Brake System   Ignition on 2 s continuous 2 DCY
Flexray P0614 - ECM/TCM Incompatible rationality check Information of transmission code is faulty   Ignition on 2 s continuous 2 DCY
Flexray P0614 - ECM/TCM Incompatible rationality check Information of engine code is faulty   Ignition on 2 s continuous 2 DCY
Flexray U0080 - Vehicle Communication Bus F communication check flexray synchronisation is faulty   Ignition on 2 s continuous 2 DCY
TCM U1103 - Production Mode Active functional check production mode active     2 s continuous 2 DCY
Gear Shift Module 1 - 3 P187A - Gear Selector 1 Engaging Process Not Successful functional check difference between measured and synchronize shaft speed 1 and Gear actuator 1-3 movement > 300 rpm and > 7 mm or < -7 mm Shaft 1 and 2 in sync position   2 s continuous 2 DCY
Gear Shift Module 4 - 6 P187D - Gear Selector 4 Engaging Process Not Successful functional check difference between measured and synchronize shaft speed 2 and Gear actuator 4-6 movement > 300 rpm and > 7 mm or < -7 mm Shaft 1 and 2 in sync position   2 s continuous 2 DCY
Gear Shift Module 5 - 7 P187C - Gear Selector 3 Engaging Process Not Successful functional check difference between measured and synchronize shaft speed 1 and Gear actuator 5-7 movement > 300 rpm and > 7 mm or < -7 mm Shaft 1 and 2 in sync position   2 s continuous 2 DCY

DAB 2-5-21