Condensation Water Drain, Checking
-- Free up the condensation water drain. Refer to Condensation Water Drain, Removing and Installing .
-- Check the condensation water drain -5- for a secure fit on the heater and A/C unit connection -1-.
Conditions
- The ridge -arrow- on the connection must engage in the guide -2-.
Conditions
- The condensation water drain -5- must not be seated loosely on the heater and A/C unit -1-.
-- The condensation water drain -1- must not sit loosely on the body opening -2-.
-- Check the distance between the condensation water drain opening -1- and the heat shield -3-.
Conditions
- There must be enough distance (dimension -x-) present so that no condensation water drains out of the condensation water drain -2-.
If the condensation water drain is seated correctly in the opening in the body and on the heater and A/C unit connection.
-- Check the condensation water drain for the aspect ratio, damage and blockage. Refer to Condensation Water Drain, Removing and Installing .