Refrigerant Circuit, Cleaning:
- Low pressure side: Refrigerant Circuits Adapter Set 1 - Adapter 12:VAS 6338/12
connected to the A/C Service Station and the Refrigerant Circuit Adapter Set - Adapter:VAS 6338/48
- High pressure side: Rinsing Adapter:VAS 6338/3A
|
Different versions:-- No adapter is necessary, the receiver/dryer is integrated into the condenser.-- Depending on the condenser version, remove the dryer cartridge from the receiver/dryer on the condenser before flushing and then seal the opening again (see note). |
- Expansion valve: Rinsing Adapter:VAS 6338/38A
- Heater and A/C Unit Refrigerant Shut-Off Valve -N541- ; install the Shut-off Valves:VAS 6338/42
- Remove the High-Voltage Battery Heater Core Refrigerant Shut-Off Valve -N542- and install the Shut-off Valves:VAS 6338/42
.
- The restrictor in the refrigerant line to the high-voltage battery heat exchanger is removed or the refrigerant line is drilled. Refer to Prepare the old restrictor for flushing: . Replace after flushing.
- Replace the Heater and A/C Unit Refrigerant Shut-Off Valve -N541- and High-Voltage Battery Heater Core Refrigerant Shut-Off Valve -N542- after flushing
|