Refrigerant Circuit, Charging

WARNING: This page is about a different car, the 2023 Volkswagen Atlas. However, it is still accessible from the selected car via links, so may be relevant.

Special tools and workshop equipment required 

Procedure 

-- Check if the new refrigerant oil in the reservoir is the correct oil type and change the oil in the reservoir if necessary.

-- Adjust the settings of the A/C Service Station that the refrigerant is filled through the high-pressure side. Refer to Owner's Manual.

CAUTION:

Risk of damage to the A/C compressor when starting it, due to liquid accumulation on the low-pressure side.

- Fill refrigerant, refrigerant oil and UV additive via the high pressure connection.

Tip

-- Refrigerant Circuit, Evacuating. Refer to REFRIGERANT CIRCUIT, EVACUATING .

-- Set the specified refrigerant capacities, refrigerant oil to be added and, if necessary, the UV additive at the A/C Service Station.

-- Start the procedure to charge the refrigerant circuit (refrigerant, if necessary refrigerant oil and UV additive) at the A/C Service Station.

-- After completion of the charging procedure A/C Service Station remove from the refrigerant circuit and turn it off. Refer to A/C SERVICE STATION, DISCONNECTING FROM THE REFRIGERANT CIRCUIT .

Vehicles with high-voltage system, for which electric activated valves in the refrigerant circuit are not open when de-energized.

-- Activate the electric activating valves of the refrigerant circuit using the Vehicle Diagnostic Tester .

Tip

For vehicles with high-voltage system and secondary functions of the A/C system, valves may be installed in the refrigerant circuit. To guarantee correct draining, evacuating and filling of the refrigerant circuit, no segments are allowed to be closed off. That is why the valves need to be closed after filling. Refer to Refrigerant Circuit .

Continuation for all vehicles

-- Depending on the completed work procedures, start the A/C system. Refer to A/C SYSTEM, OPERATING AFTER CHARGING .