Electrically-Driven A/C Compressor, Cleaning

WARNING: This page is about a different car, the 2023 Volkswagen Atlas. However, it is still accessible from the selected car via links, so may be relevant.

Special tools and workshop equipment required 

Procedure 

-- Pour out as much refrigerant oil as possible via the refrigerant line connections.

Tip

If refrigerant oil from a new A/C compressor is poured into a clean container and this container is sealed air tight afterward, then it can be used to adjust the refrigerant oil capacity later on.

-- Connect the A/C compressor with the A/C service station. Refer to MAIN WIRING DIAGRAM, ELECTRICALLY-DRIVEN A/C COMPRESSOR, CLEANING .

-- Position the A/C compressor so that the high-pressure side output is as low as possible. This will guarantee best possible results of draining the A/C compressor.

-- Select program for flushing.

-- Clean the A/C compressor.

Tip

Depending on version of the A/C Service Station, old oil container holds only approximately 125 cm 3 refrigerant oil, in the event a system with a larger quantity of refrigerant oil must be flushed, it may be necessary to drain the old oil container after the first flushing process of one flushing cycle.

-- After completion of the flushing procedure, check the refrigerant circuit pressure. There must not be any pressure in the A/C compressor (evacuate the refrigerant circuit briefly once more if necessary).

CAUTION:

Danger of frostbite due to refrigerant coming out under pressure.

Frostbite on the skin and other parts of the body is possible.

- Wear safety gloves.

- Wear protective eyewear.

- Evacuate or drain refrigerant and open the refrigerant circuit immediately.

- If more than 10 minutes elapse after extracting or draining the refrigerant and the refrigerant circuit has not been opened, extract or drain the refrigerant again. Pressure develops in the refrigerant circuit due to evaporation.

-- Remove the refrigerant line connection from the A/C compressor to the A/C Service Station.

-- Perform the adjustment of the amount of refrigerant oil in the refrigerant circuit, depending on the complaint. Refer to COMPONENTS, REPLACING  and REFRIGERANT OIL CAPACITIES .