Overview - Condenser

WARNING: This page is about a different car, the 2021 Volkswagen Tiguan, 2020 Volkswagen Tiguan, 2019 Volkswagen Tiguan, 2018 Volkswagen Tiguan Limited, and 2018 Volkswagen Tiguan. However, it is still accessible from the selected car via links, so may be relevant.

Condenser, Receiver/Dryer

NOTE:

The image shows a Modine condenser.

For A/C systems with refrigerant R1234yf, the desiccant bag/dryer cartridge must be replaced each time the refrigerant circuit is opened. Refer to COMPONENTS, REPLACING .

Under certain conditions, the desiccant bag no longer needs to be replaced each time the refrigerant circuit is opened on A/C systems with refrigerant R134a. Refer to Components, Replacing .

GWWA87-11376Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.
  1. Condenser
  2. Seal
    • Replace after removing.
    • There are different versions. Refer to the Parts Information.
    • Coat with refrigerant oil before installing.
  3. Refrigerant Line
    • To the inner heat exchanger
  4. Bolt
    • 8 Nm
  5. Bolt
    • 8 Nm
  6. Refrigerant Line
    • From the A/C compressor
  7. Seal
    • Replace after removing.
    • There are different versions. Refer to the Parts Information.
    • Coat with refrigerant oil before installing.
  8. Bracket
    • For the refrigerant lines
  9. Cap
    • Modine: 3 Nm
    • There are different versions. Refer to the Parts Information.
  10. Snap Ring
  11. Cap
    • Replace if damaged
    • There are different versions. Refer to the Parts Information.
  12. Seal
    • Replace after removing.
    • There are different versions. Refer to the Parts Information.
    • Coat with refrigerant oil before installing.
  13. Desiccant Bag
  14. Screen
  15. Receiver/Dryer
    • There are different versions. Refer to the Parts Information.
    • Is integrated in the condenser on this version
      NOTE:

      Under certain conditions, the receiver/dryer with desiccant bag no longer needs to be replaced after every time the refrigerant circuit is opened. Refer to COMPONENTS, REPLACING or Components, Replacing .