Information For Vehicles With Start/Stop System
If the vehicle has a Start/Stop system, perform the following termination conditions to deactivate the Start/Stop function:
- The Start/Stop system was turned off with the Start/Stop mode button.
- The battery charge level does not make it possible to start the engine again (start voltage prediction).
- The defrost function is active.
- The windshield defogger is active.
- The selected temperature deviates more than 8 °C (46 °F) from the actual interior temperature.
- The engine speed exceeds 1200 RPM.
- The Generator -C- is faulty, for example, the ribbed belt is torn.
- Coolant temperature not in specified range of 25 °C - 100 °C (77° - 212 °F).
- Increasing the blower speed by more than four increments.
Additional information:
- Refer to Self Study Program 426 Start/Stop System 2009 for more information.