Home >> Volkswagen >> 2021 >> Jetta R-Line, Automatic Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 162 (General, Technical Data (Refrigerant R1234YF Servicing)) >> 00 General, Technical Data >> Technical And Physical Principles >> Pyrotechnical Characteristics >> Refrigerant R1234YF Analysis
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Refrigerant R1234YF Analysis

WARNING: This page is about a different car, the 2021 Volkswagen Tiguan, 2020 Volkswagen Tiguan, 2019 Volkswagen Tiguan, 2018 Volkswagen Tiguan Limited, and 2018 Volkswagen Tiguan. However, it is still accessible from the selected car via links, so may be relevant.

It is necessary for the operation of the A/C system that the refrigerant used has a certain purity.

NOTE:

Faulty gas analysis is possible due to air in the refrigerant hose or not following the procedure of the gas analysis according to the Owner's Manual.

Pay exact attention to the gas analyzer/A/C Service Station Owner's Manual.

Evacuate the refrigerant hose from the A/C Service Station before connecting the service couplings to the refrigerant circuit/a natural gas fuel tank with refrigerant R1234yf. Refer to the gas analyzer/A/C Service Station Owner's Manual and REFRIGERANT GAS ANALYSIS, PERFORMING .

Contamination with other refrigerants or gases can case damage and lead to failure of the A/C system and the A/C Service Station.

Contaminated refrigerant must be analyzed as a gas of an unknown composition according to the legal requirements and then recycled (or disposed). Refer to REFRIGERANT GAS ANALYSIS, PERFORMING .

NOTE:

Return the contaminated refrigerant R1234yf for analysis to the refrigerant supplier. If because of the damage on the refrigerant circuit, which has already occurred or is expected it must be known with which foreign substance the refrigerant is contaminated, perform the corresponding claim to request the analysis findings. Refer to RETURN OF CONTAMINATED REFRIGERANT R1234YF FOR ANALYSIS, PREPARATION OR DISPOSAL .

The following values apply for a gas analysis of clean refrigerant R1234yf:

NOTE:

So that fluids components (for example drops of refrigerant oil) in the extracted refrigerant gas does not lead to a faulty result of the gas analysis, a separator (filter) is installed in the gas analyzer which separates the fluid drops. Replace the separator according to the specification of the gas analyzer for example the Owner's Manual belonging to the A/C Service Station. Refer to the Gas Analyzer Owner's Manual or Owner's Manual A/C Service Station.