Overview - Condenser, MODINE
Condenser, Receiver/Dryer
Under certain conditions, the desiccant bag/dryer cartridge no longer needs to be replaced each time the refrigerant circuit is opened on A/C systems with refrigerant R1234yf. Refer to COMPONENTS, REPLACING .
Under certain conditions, the desiccant bag no longer needs to be replaced each time the refrigerant circuit is opened on A/C systems with refrigerant R134a. Refer to the appropriate service information .
The image shows a Modine condenser.
- Condenser
- There are different versions. Refer to the Parts Information.
- Removing and Installing. Refer to CONDENSER, REMOVING AND INSTALLING .
- Seal
- Replace after removing.
- There are different versions. Refer to the Parts Information.
- Coat with refrigerant oil before installing.
- Refrigerant Line
- To the inner heat exchanger
- Bolt
- 8 Nm
- Bolt
- 8 Nm
- Refrigerant Line
- From the A/C compressor
- Seal
- Replace after removing.
- There are different versions. Refer to the Parts Information.
- Coat with refrigerant oil before installing.
- Bracket
- For the refrigerant lines
- Cap
- Modine: 3 Nm
- There are different versions. Refer to the Parts Information.
- Snap Ring
- Cap
- Replace if damaged
- There are different versions. Refer to the Parts Information.
- Seal
- Replace after removing.
- There are different versions. Refer to the Parts Information.
- Coat with refrigerant oil before installing.
- Desiccant Bag
- There are different versions. Refer to the Parts Information.
- Removing and Installing:
- Denso condenser. Refer to DESICCANT BAG, REMOVING AND INSTALLING, DENSO CONDENSER .
- Modine condenser. Refer to DESICCANT BAG, REMOVING AND INSTALLING, MODINE CONDENSER .
- Screen
- There are different versions. Refer to the Parts Information.
- Removing and Installing
- Denso condenser. Refer to DESICCANT BAG, REMOVING AND INSTALLING, DENSO CONDENSER .
- Modine condenser. Refer to DESICCANT BAG, REMOVING AND INSTALLING, MODINE CONDENSER .
- Receiver/Dryer
- There are different versions. Refer to the Parts Information.
- Is integrated in the condenser on this versionNOTE:
Under certain conditions, the desiccant bag/dryer cartridge no longer needs to be replaced each time the refrigerant circuit is opened on A/C systems with refrigerant R1234yf. Refer to COMPONENTS, REPLACING .
Under certain conditions, the desiccant bag no longer needs to be replaced each time the refrigerant circuit is opened on A/C systems with refrigerant R134a. Refer to the appropriate service information .