Calibration Preparation Work: Notes
Special tools and workshop equipment required
- Calibration Unit - VAS6350A-
- Calibration Tool - Wheel Center Mounting - VAS6350/1A-
- Vehicle Diagnostic Tester
There is much preparation work that must be performed before calibrating using the Vehicle Diagnostic Tester.
Requirements:
- Move the vehicle onto a secure flat surface.
- Apply the parking brake - the vehicle must not move during the measurement.
- Place the front wheels in a straight-ahead position - steering wheel neutral position.
- No persons may be in the vehicle interior during the measurement.
- Do not open and close the vehicle doors during calibration.