Overview - Transmission
- Transmission Fluid Pan
- Removing and installing. Refer to TRANSMISSION FLUID PAN, REMOVING AND INSTALLING .
- Gasket
- Replace after removing
- Bolt
- Replace after removing
- Tightening specification and sequence. Refer to Figure.
- For attaching the DSG Transmission Mechatronic -J743- to the transmission housing
- Quantity: 10
- DSG Transmission Mechatronic -J743-
- Allocate using the transmission code letters. Refer to the Parts Information.
- Removing and installing. Refer to MECHATRONIC, REMOVING AND INSTALLING .
- Bolt
- Tightening specification and sequence. Refer to Figure.
- Replace after removing
- Quantity: 5
- Clutch End Cover
- For the dual clutch
- Removing and installing. Refer to CLUTCH END COVER, REMOVING AND INSTALLING .
- Dual Clutch
- Removing. Refer to DUAL CLUTCH, REMOVING .
- Installing. Refer to DUAL CLUTCH, INSTALLING .
- Bleed Pipe
- Replace after removing
- Pressed into the transmission housing
- Bleed Cap
- Placed on bleed pipe
- Nut
- 20 Nm
- Selector Lever
- Insert so that master spline aligns with shift rod
- Seal
- Replacing. Refer to SELECTOR SHAFT SEAL, REPLACING .
- Bolt
- 20 Nm +90°
- Replace after removing
- Transmission Fluid Cooler
- Removing and installing. Refer to TRANSMISSION FLUID COOLER, REMOVING AND INSTALLING .
- O-rings
- Replace after removing
- Cable Bracket
- For the selector lever cable
- Bolt
- 20 Nm +90°
- Replace after removing
- Quantity: 2
- Filter Housing
- 20 Nm
- O-ring
- Replace after removing
- Transmission Fluid Filter
- Information on changing filter. Refer to TRANSMISSION FLUID FILTER, REMOVING AND INSTALLING .
- Replacing. Refer to TRANSMISSION FLUID .
- Ignore, Discontinued
- Ignore, Discontinued
- Alignment Pin
- For centering the transmission fluid pump to the transmission housing
- Quantity: 2
- Seal
- Replace after removing
- Transmission Fluid Pump
- Removing and installing. Refer to TRANSMISSION FLUID PUMP, REMOVING AND INSTALLING .
- Transmission Fluid Pump Cover
- Replace after removing
- Removing and installing. Refer to TRANSMISSION FLUID PUMP, REMOVING AND INSTALLING .
- With seal
- Bolt
- Replace after removing
- Tightening specification and sequence. Refer to Figure.
- Quantity: 4
- Bolt
- Replace after removing
- Quantity: 4
- Overflow Pipe
- 3 Nm
- Plastic
- To drain the transmission fluid, remove the drain and check plug -item ) OVERVIEW - TRANSMISSION - List Item: Fluid Drain and Check Plug and remove the overflow pipe.
- The length of the overflow pipe determines the fluid level inside the transmission
- Allocate according to the Parts Information.
- Seal
- Replace after removing
- Fluid Drain and Check Plug
- 45 Nm
- There is an overflow pipe with a 8 mm inner hex behind this bolt -item ) OVERVIEW - TRANSMISSION - List Item: Overflow Pipe
- Drain the transmission fluid via the drain- and check plug and removed overflow pipe.