Adaptive Cruise Control (ACC), Calibrating, Arteon: Notes
Special tools and workshop equipment required
- Setting Device - Basic Set - VAS6430/1- or Setting Device - Basic Set - VAS6430/1A-
- ACC Reflector Mirror - VAS6430/10-
- Wheel Alignment Computer
Before adjusting the adaptive cruise control (ACC). check the sensor and its mounts and attachments for damage. external influences and secure fit. Repair any damaged components.
Prior to adjusting the adaptive cruise control (ACC). check the event memory and correct any malfunctions.
The ACC control module "adjustment angle measured value" shows whether the sensor is misaligned.
The ACC adjustment may only be set using a VW/Audi-approved wheel alignment device and adjustment equipment!
Proper ACC operation requires correct alignment.
- Under the following conditions the Control Module for Adaptive Cruise Control - J428- must be calibrated:
- Control Module for Adaptive Cruise Control - J428- was replaced
- The lock carrier service position was performed
- The lock carrier was removed and installed.
- The lock carrier was replaced
- The adjustment angle is outside of the tolerance. Perform a tolerance check using the Vehicle Diagnostic Tester.
- The rear axle toe were replaced.
- Changes were made to the suspension that affect the height.
NOTE:
- Before driving the vehicle onto the alignment stand. make sure there is enough space between the vehicle and the Setting Device - Basic Set - VAS6430/1A-. The distance between the Setting Device - Basic Set - VAS6430/1A-and the sensor must be 120 cm ± 2.5 cm.
- If there is not sufficient space, drive the vehicle backward onto the alignment stand in order to use the corresponding space.
- If the ACC Reflector Mirror - VAS6430/10- is repositioned on the calibration beam during the adjustment. the Setting Device - Basic Set - VAS6430/1A- setting must always be checked (for example. bubble levels. individual toe settings at the calibration beam. etc.).
- Before beginning the adjustment, check the DTC memory and correct any malfunctions present.
The adjustment procedure is described here using the Setting Device Basic Set - VAS6430/1-.