Condenser, Removing And Installing: Installing
Install in reverse order of removal and note the following:
-- There is refrigerant oil in the removed condenser that must be redelivered to the refrigerant circuit (with new condenser). Refer to Refrigerant Circuit Components, Replacing or COMPONENTS, REPLACING .
-- Evacuate and charge the refrigerant circuit. Refer to Refrigerant Circuit or Working with A/C Service Station (1 Of 2) / Working with A/C Service Station (2 Of 2) .
-- Initiate the basic setting of the A/C system through the Thermal Management Control Module -J1024- and activate the power-controlled valves using one of the routines stored there. "Charge/flush the refrigerant circuit stop routine" using the Vehicle Diagnostic Tester in the "Guided Fault Finding" function.