Condenser, Removing And Installing: Installing
Install in reverse order of removal and note the following:
Procedure when installing a new A/C compressor
-- Determine the refrigerant oil quantity of the removed A/C compressor by letting drain in a measuring container.
Catch the refrigerant oil from the new A/C compressor for reuse in a suitable container.
-- Drain the refrigerant oil from the new A/C compressor.
-- Add the quantity of refrigerant oil determined from the remove A/C compressor, in equal amounts in the empty new A/C compressor.
-- Coat the new seals with refrigerant oil before installing the refrigerant line.
- Never start the engine with the refrigerant circuit empty.
Vehicles with Refrigerant R134a
-- Fill the refrigerant circuit. Refer to WORKING WITH A/C SERVICE STATION .
-- Perform the leak test on the closed line connections of the refrigerant circuit. Refer to REFRIGERANT CIRCUIT .
Vehicles with Refrigerant R1234yf
-- Fill the refrigerant circuit. Refer to appropriate service information. .
-- Perform the leak test on the closed line connections of the refrigerant circuit. Refer to REFRIGERANT CIRCUIT .