Possible Concerns

WARNING: This page does not describe the selected car, but rather 9 other vehicles, including the 2018 Audi S6, 2018 Audi A6 Quattro, 2018 Audi A6, 2017 Audi S6, and 2017 Audi A6 Quattro. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:

For all complaints marked *. Refer to PRESSURES, CHECKING "Checking pressures".

If a malfunction occurs at only one evaporator in vehicles with two evaporators, also check the pressures in the refrigerant circuit.

Observe the test requirements. Refer to TEST REQUIREMENTS .

Vehicles without a High-Voltage System 

Vehicles with a High-Voltage System 

All Vehicles 

From these, the following complaints may also occur:

The A/C Compressor Makes Noises

-- Tighten compressor securing bolts and compressor bracket using a torque wrench.

-- Check the routing of refrigerant lines; they must not touch other components and must not be subject to strain (align if necessary).

Noise (Refrigerant Hammer) Occurring Immediately after Switching on Air Conditioner and/or When Cornering or Braking

-- Discharge, evacuate and charge refrigerant circuit (too much refrigerant in circuit).

NOTE:

Too much refrigerant oil in the circuit could also cause this problem. This could occur if the amount of refrigerant oil was not adjusted when replacing the A/C compressor.

Water Sprays out of Vents (in Dash Panel or Footwell) Although Air Conditioning System is Otherwise Functioning Properly: 

-- Check proper routing of condensate drain; it must not be crushed or kinked.

-- Check condensation drain valve, it must not be clogged by wax or underbody sealant and must close properly.

-- Check plenum chamber cover; it must not be damaged and must be properly installed (to stop water running into evaporator).

-- Check the water drains in plenum chamber; they must not be blocked (for example, by leaves).