Fresh Air Blower Control Module -J126-, Removing And Installing: Removing
-- Remove the partition. Refer to COMPONENT LOCATION OVERVIEW - STORAGE COMPARTMENT AND COVERS .
-- Disconnect the connectors -1 and 3-.
-- Remove the bolts -arrows-.
CAUTION:
There is a risk of burns from the hot radiating surfaces on the control module.
It Is Possible To Burn Hands.
- Wear safety gloves.
-- Remove the control module -2- from the Fresh Air Blower -V2-.