MULTIFUNCTION Transmission Range Switch, Adjusting
Special tools and workshop equipment required
- Gauge - Multi Function Switch: T10173
-- Move the selector lever into "N".
-- Do not bend the selector lever cable.
Adjustment Requirements:
- Selector lever cable is removed from the lever/selector shaft
- The selector shaft is in "N".
- The bolts on the Multifunction Transmission Range Switch -F125- are loosened.
- The lever/selector shaft is removed.
Adjusting
-- Place the : T10173 on the selector shaft -2- and turn the Multifunction Transmission Range Switch -F125- -1- until the : T10173 locks onto the connector tab on the Multifunction Transmission Range Switch -F125-.
If the connector tab cannot engage into the : T10173 groove, then the transmission is no longer in "N". If this is the case, shift the transmission into "N" using the : T10173 .
-- Secure the : T10173 on the selector shaft -2- with the bolt -3-.
-- Tighten the bolts -arrows- to the tightening specification.
-- Remove the : T10173 .
-- Further installation is performed in reverse order of removal. Refer to MULTIFUNCTION TRANSMISSION RANGE SWITCH, REMOVING AND INSTALLING .
Tightening Specifications
| Component | Tightening Specification |
|---|---|
| Multifunction Transmission Range Switch -F125- to transmission housing | 6 Nm |