Refrigerant Circuit Pressure Sensor -G805-, Removing And Installing: Notes
Special Tools And Workshop Equipment Required
- Socket - 24mm:T40284
- Torque Wrench 1410:VAG1410
- Engine Bung Set:VAS6122
NOTE:
The Refrigerant Circuit Pressure Sensor -G805- can be removed without bleeding the refrigerant circuit.
There is a check valve installed in the refrigerant line.
If refrigerant drips out of the refrigerant line for longer than one second when loosening the Refrigerant Circuit Pressure Sensor -G805-, then retighten the Refrigerant Circuit Pressure Sensor -G805-. The check valve inside the refrigerant pipe is faulty and must be replaced.
Removal and installation of the check valve is the same as removing and installing the evacuating and charging valve on the low pressure and high pressure side. Refer to EVACUATING AND CHARGING VALVE, REMOVING AND INSTALLING, LOW AND HIGH PRESSURE SIDE .