Home >> Volkswagen >> 2016 >> Golf Base, Eng CD CXBA, Automatic Trans >> Repair and Diagnosis >> Electrical >> Charging Systems >> Electrical System (Charging System, Starting System & Cruise Control System - Service Information) >> 27 Battery, Starter, Generator, Cruise Control >> Battery >> Battery, Disconnecting And Connecting >> Connecting
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Battery, Disconnecting And Connecting: Connecting

Pay attention to the following when disconnecting the Battery -A-.

-- Release and disconnect the connector -2- from the Battery Monitoring Control Module -J367- -3-.

GWWA27-10252Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.

-- Install the battery ground cable terminal clamp by hand on the battery negative terminal "-".

-- Tighten the nut -1- to the tightening specification.

-- Reconnect the connector -2- to the Battery Monitoring Control Module -J367-.

-- Turn on the ignition.

-- Check the time and if necessary adjust.

-- Window, open and close all the way.

-- Then, with the windows closed, pull the power window switch until the relay audibly switches.

-- Check the window regulator convenience switch.

While comfort switching is operated, window must close without holding the power window switch.

NOTE:

After connecting the power supply, the ASR/ESP Indicator Lamp -K155- may only go out after the vehicle has been driven a few yards.