19.8.3 Peripheral Camera Calibration Device - VAS6350/6-, Aligning
Special Tools And Workshop Equipment Required
- Calibration Tool - VAS6350-
- Peripheral Camera Calibration Device - VAS6350/6-
The Peripheral Camera Calibration Device - VAS6350/6- is comprise of the following individual parts:
- Peripheral Camera Calibration Device - Left Post With Plate - VAS6350/6-1-
- Peripheral Camera Calibration Device - Right Post With Plate - VAS6350/6-2-
- Peripheral Camera Calibration Device - Left Post Mount - VAS6350/6-3-
- Peripheral Camera Calibration Device - Right Post Mount - VAS6350/6-4-
- Peripheral Camera Calibration Device - Guide Pin - VAS6350/6-5-
- Line Laser Mount - VAS6350/6-6-
- Install the - VAS6350/6-.
NOTE:
- The -VAS6350/6-1- and the -VAS6350/6-2- must be vertical.
- Line up the plates so that the air bubble in the level is exactly in the center of the indicator -arrow-.
- Set the -VAS6350/6-1- -1- and the -VAS6350/6-2- -2- to dimension -B- 77.5 on both sides of the scale on the calibration device.
- Adjust the height of the -VAS6350/6-1- -1- and the - VAS6350/6-2- -2- so that dimension -A- is 150 mm between the lower edge of the black measuring field (not of the aluminum frame) and the surface of the calibration device.
NOTE:
The corners on the outside of the calibration device base plate must always be flush with the outer edge of the black line on the measuring field when performing distance measuring.