Work Procedure
-- Connect the scan tool.
-- Start the engine and let run at idle speed.
-- Select Mode 6: Check test the results of components that are not continuously monitored.
Select the desired Test-ID.
The current minimum and maximum values will be displayed on the scan tool screen.
The following table is a numerical list of all "Test-IDs" that may be selected.
| Monitor-ID (Hex-ID) | Component or System |
|---|---|
| $01:Monitor-ID $01: Oxygen Sensor Monitor Bank 1 - Sensor 1 | Oxygen Sensor Monitor Bank 1 - Sensor 1 |
| $02:Monitor-ID $02: Oxygen Sensor Monitor Bank 1 - Sensor 2 | Oxygen Sensor Monitor Bank 1 - Sensor 2 |
| $21:Monitor-ID $21: Catalytic Converter Monitoring | Catalytic Converter Monitoring |
| $31:Monitor-ID $31: EGR Monitor Bank 1 | EGR Monitoring |
| $81:Monitor-ID $81: Fuel System Monitor Bank 1 | Fuel System Monitor Bank 1 |
| $85:Monitor-ID $85: Boost Pressure Control Monitor Bank 1 | Boost Pressure Control Monitor Bank 1 |
| $98:Monitor-ID $98: NOx Catalyst Monitor Bank 1 | NOx Catalyst Monitor Bank 1 |
| $A2:Monitor-ID $A2: Mis-Fire Cylinder 1 Data | Mis-Fire Cylinder 1 Data |
| $A3:Monitor-ID $A3: Mis-Fire Cylinder 2 Data | Mis-Fire Cylinder 2 Data |
| $A4:Monitor-ID $A4: Mis-Fire Cylinder 3 Data | Mis-Fire Cylinder 3 Data |
| $A5:Monitor-ID $A5: Mis-Fire Cylinder 4 Data | Mis-Fire Cylinder 4 Data |
| $B2:Monitor-ID $B2: Particulate Matter Trap Efficiency | Particulate Matter Filter Monitor Bank 1 |