Reducing Agent Metering System Delivery Unit -GX19-, Checking: Notes
General Description
The Reducing Agent Metering System Delivery Unit -GX19- supplies reducing agent to the Reducing Agent Injector -N474- at a pressure of 72.5 psi (5 bar) when activated via a Pulse Width Modulated (PWM) signal by the Engine Control Module -J623-.
The Reducing Agent Metering System Delivery Unit -GX19- contains the following components:
- Reducing Agent Tank Heater (Heating Circuit 1) -Z102-
- Reducing Agent Temperature Sensor -G685-
- Reducing Agent Reservoir Sensor -G697-
- Reducing Agent Return Flow Pump -V561-
- Reducing Agent Pump -V437-
The Reducing Agent Metering System Delivery Unit -GX19- components cannot be serviced separately, and must be serviced as a unit.
Special Tools And Workshop Equipment Required
- Multimeter.
- Wiring Diagram.
- Scan Tool.
Test Requirements
- Fuses OK.
- Battery voltage OK.
- Switch OFF all electrical and electronic accessories.
- Vehicles with Auto. Transmission, ensure Selector Lever position is in "P".
- Vehicles with Man. Transmission, ensure Shifter Lever position is in "N" with Parking Brake applied.
- Observe all safety precautions: SAFETY PRECAUTIONS .
- View clean working conditions: CLEAN WORKING CONDITIONS .
- For Hybrid vehicles refer to: HIGH VOLTAGE SYSTEM GENERAL WARNINGS .