Fastener Tightening Specifications: Notes
| Component | Fastener Size | Nm | ||||
|---|---|---|---|---|---|---|
| Cable Bracket to Transmission Bolt (1) | - | 20 + 90° | ||||
| Drain and Inspection Plug to Transmission | - | 45 | ||||
| Oil Filter Housing to Transmission | - | 20 | ||||
| Oil Pump Cover Bolt (2) | - | 8 | ||||
| Overflow Tube to Transmission | - | 3 | ||||
| Selector Housing to Body Nut | - | 8 | ||||
| Selector Lever Cable Adjustment Bolt | - | 13 | ||||
| Selector Mechanism with Selector Lever and Selector Lever Cable to Body Bolt | - | 8 | ||||
| Selector Shaft Lever to Selector Shaft Nut | - | 20 | ||||
| Transmission Cover Bolt (2) | - | 10 | ||||
| Transmission Oil Cooler to Transmission Bolt (1) | - | 20 + 90° | ||||
| Transmission Input Speed and Clutch Oil Temperature Sensor Bolt | - | 10 | ||||
| Transmission Mount Bracket to Transmission Bolt | - | 40 + 90° | ||||
| Transmission Mount to Transmission Mount Bracket Bolt | - | 60 + 90° | ||||
| Wire Bracket to Transmission Cover Nut | - | 10 | ||||
|
||||||
Mechatronic Unit Bolt Tightening Sequence and Specification
-- Install new bolts -1 through 10- hand tight.
-- Tighten the bolts in the specified sequence to 5 Nm + 90° (1/4) additional turn.
Oil Pump Bolt, Variety and Tightening Specification
All 4 bolts with a flat heads
-- Tightening specification: 5 Nm + 90° (1/4) additional turn
3 bolts have a flat head, the upper bolt is countersunk
Tightening specification:
- Countersunk bolt: 8 Nm without tightening angle (tighten using Special Wrench, Long Reach T10054)
- Flat head bolts: 8 Nm + 90° (1/4) additional turn