Information For Vehicles With Start/Stop System
If the vehicle has a start-stop system, perform the following termination conditions to deactivate the start-stop function:
- Use the Start/Stop button to switch off the Start/Stop System.
- The battery charge level does not make it possible to start the engine again (start voltage prediction).
- The defrost function is active.
- The windshield defogger is active.
- The selected temperature deviates more than 8 °C (46.4 °F) from the actual temperature inside the vehicle.
- The engine speed exceeds 1, 200 RPM.
- The Generator -C- is faulty, for example, the ribbed belt is torn.
- The coolant temperature is not in the specified range of 25 °C to 100 °C (77 to 212 °F).
- Increasing the blower speed by more than four increments.
Further Information:
- Refer to Self Study Program No. 426; Start/Stop System 2009 for more information.