Control Module, Removing From Hydraulic Unit
NOTE:
-- Set the hydraulic unit with the control module upward on a clean, level surface.
-- Remove the inner TORX® bolt from the control module.
-- Pull control module off from hydraulic unit -arrow- without angling.
WARNING:
- The circuit board is laid open on a disconnected control module.
- No moisture or dirt particles must get into the control module.
- Avoid build-up of static electricity!
-- Cover control module magnetic coils with a lint free cloth.
After separating the control module and hydraulic unit, use transport protection for valve body.