| P062F |
ECU EEPROM check |
|
--- |
--- |
|
| P0A1F |
Battery Energy Control Module |
- Monitor signal for contactor power circuit is High
- Monitor signal for contactor power latch circuit is Low
- Monitor signal for power sustain circuit in (input signal to CPU from H/W) is High (input signal to CPU from H/W)
- Watch Dog counter > 50 count (increment 10 ms cycle during malfunction detection)
|
- Battery state HV OFF or Precharge or HV_ON
|
1.0 Sec |
|
| P0A80 |
Hybrid/EV Battery Pack Current Sensor "A" Circuit Range/Performance |
- Internal resistance > 4.45 to 1.29 Ω
|
- battery state: HV_ON
- temperature >= -5 and <= 40
- battery load discharge >= 3.24 and <= 31.05 kW
- battery load charge >= 3.24 and <= 11.61 kW
- battery load dischanrge >= 31.05 and <= 62.19 kW (one value)
- battery load charge >= 11.61 and <= 23.31 kW (one value)
- maximum monitoring time 60 sec
- Less Performance counter >= 5 times
|
300 Sec |
|
| P0A95 |
High Voltage Fuse "A" |
- Status information from V Sensor indicates fuse malfunction
|
- Battery state HV OFF or Precharge or HV_ON
|
0.10 Sec |
|
| P0A9D |
Hybrid/EV Battery Temperature Sensor "A" Circuit Low |
- Temperature sensor x > 94° C
|
- Battery state HV OFF or Precharge or HV_ON or Emergency OFF
|
0.60 Sec |
|
| P0A9E |
Hybrid/EV Battery Temperature Sensor "A" Circuit Low |
- Temperature sensor x > 94° C
|
- Battery state HV OFF or Precharge or HV_ON or Emergency OFF
|
0.60 Sec |
|
| P0AA1 |
Hybrid/EV Battery Positive Contactor Circuit Stuck Closed |
- State 1: all contactors off inconsistency
- State 2: control negative contactor to close inconsistency
- State 3: control precharge contactor to close inconsistency
- State 4: control positive contactor to close inconsistency
- State 5: control precharge contactor to open in case of malfunction of state 1 to 5 to pin-point: inconsistency
- State 6: control negative contactor to open inconsistency
|
|
--- |
|
- (HVP - CVP) * 100 / HVP <= 20 %
OR
- (HVN - CVN) * 100 / HVN <= 20 %
|
|
| P0AA2 |
Hybrid/EV Battery Positive Contactor Circuit Stuck Open |
- State 1: all contactors off inconsistency
- State 2: control negative contactor to close inconsistency
- State 3: control precharge contactor to close inconsistency
- State 4: control positive contactor to close inconsistency
- State 5: control precharge contactor to open in case of malfunction of state 1 to 5 to pin-point: inconsistency
- State 6: control negative contactor to open inconsistency
|
|
--- |
|
- BECM requests to closed
- Battery current < 0, 2 A
- (TV-High - CVP) * 100 / Pack voltage > 20 %
- (TV-Low - CVN) * 100 / Pack voltage > 20 %
|
|
1 s |
| P0AA4 |
Hybrid/EV Battery Negative Contactor Circuit Stuck Closed |
- State 1: all contactors off inconsistency
- State 2: control negative contactor to close inconsistency
- State 3: control precharge contactor to close inconsistency
- State 4: control positive contactor to close inconsistency
- State 5: control precharge contactor to open in case of malfunction of state 1 to 5 to pin-point: inconsistency
- State 6: control negative contactor to open inconsistency
|
|
--- |
|
- (HVP - CVP) * 100 / HVP <= 20 %
OR
- (HVN - CVN) * 100 / HVN <= 20 %
|
|
| P0AA5 |
Hybrid/EV Battery Negative Contactor Circuit Stuck Open |
- State 1: all contactors off inconsistency
- State 2: control negative contactor to close inconsistency
- State 3: control precharge contactor to close inconsistency
- State 4: control positive contactor to close inconsistency
- State 5: control precharge contactor to open in case of malfunction of state 1 to 5 to pin-point: inconsistency
- State 6: control negative contactor to open inconsistency
|
|
--- |
|
- BECM requests to closed
- Battery current < 0.2 A
- (TV-High - CVP) * 100 / Pack voltage > 20 %
- (TV-Low - CVN) * 100 / Pack voltage > 20 %
|
|
1 s |
| P0AAD |
Hybrid/EV Battery Pack Air Temperature Sensor "A" Circuit Range/Performance |
- average of battery temperature - inlet/outlet thermistor temperature > 10° C
- |inlet thermistor temperature - outlet thermistor temperature > 10° C
- engine off time > 360 min
|
|
10 Sec |
|
| P0AAE |
Hybrid/EV Battery Pack Air Temperature Sensor "A" Circuit Low |
- Thermistor temperature < -45.0° C
|
- Battery state HV OFF or Precharge or HV_ON
|
10 Sec |
|
| P0AAF |
Hybrid/EV Battery Pack Air Temperature Sensor "A" Circuit High |
- Thermistor temperature > 95.0° C
|
- Battery state HV OFF or Precharge or HV_ON
|
10 Sec |
|
| P0AB2 |
Hybrid/EV Battery Pack Air Temperature Sensor "B" Circuit Range/Performance |
- average of battery temperature - inlet/outlet thermistor temperature > 10° C
- inlet thermistor temperature - outlet thermistor temperature > 10° C
- engine off time > 360 min
|
|
10 Sec |
|
| P0AB3 |
Hybrid/EV Battery Pack Air Temperature Sensor "B" Circuit Low |
- Thermistor temperature < -45.0° C
|
- Battery state HV OFF or Precharge or HV_ON
|
10 Sec |
|
| P0AB4 |
Hybrid/EV Battery Pack Air Temperature Sensor "B" Circuit High |
- Thermister temperature > 95.0° C
|
- Battery state HV OFF or Precharge or HV_ON
|
10 Sec |
|
| P0ABA |
Hybrid/EV Battery Pack Voltage Sense "A" Circuit |
- cell controller communication is missing at least one cell controller
|
- Battery state HV OFF or Precharge or HV_ON
|
0.70 Sec |
|
| P0ABB |
Hybrid/EV Battery Pack Voltage Sense "A" Circuit Range/Performance |
- Negative contactor voltage > 1.15 V negative total cell voltage
- or
- Negative contactor voltage < 0.85 V negative total cell voltage
- or
- Positive contactor voltage > 1.15 V positive total cell voltage
- or
- Positive contactor voltage < 0.85 V positive total cell voltage V
|
|
0.10 Sec. |
|
| P0ABC |
Hybrid/EV Battery Pack Voltage Sense "A" Circuit Low |
- Negative contactor voltage > 258 V
- or
- Negative contactor voltage < -258 V
- or
- Positive contactor voltage > 258 V
- or
- Positive contactor voltage < -258 V
|
|
0.10 Sec. |
|
| P0AC0 |
Hybrid/EV Battery Pack Current Sensor "A" Circuit Range/Performance |
- Battery current > 130 A
- Battery current < -190 A
|
|
0.50 Sec |
|
- compare P-GND voltage polarization with Current polarization inconsistency
|
- Battery state HV_ON.
- voltage over fuse < -120 mV
- voltage over fuse > 120 mV
|
1 Sec |
- current offset > 1 A
- current offset < -2 A
|
- battery state: during initialization
|
10 Sec |
- State 1: all contactors off inconsistency
- State 2: control negative contactor to close inconsistency
- State 3: control precharge contactor to close inconsistency
- State 4: control positive contactor to close inconsistency
- State 5: control precharge contactor to open in case of malfunction of state 1 to 5 to pin-point: inconsistency
- State 6: control negative contactor to open inconsistency
|
- battery state: Pre-charge
|
--- |
|
| P0AC1 |
Hybrid/EV Battery Pack Current Sensor "A" Circuit Low |
|
|
0.10 Sec |
|
| P0AC2 |
Hybrid/EV Battery Pack Current Sensor "A" Circuit High |
|
|
0.10 Sec |
|
| P0AC6 |
Hybrid/EV Battery Temperature Sensor "B" Circuit Range/Performance |
- difference of two temperature sensors < -20° C
OR
- difference of two temperature sensors > 20° C
- Number of checks with a single sensor exceeds threshold value >= 5
|
- Battery state HV OFF or Precharge or HV_ON or Emergency OFF
|
10 Sec |
|
| P0AC7 |
Hybrid/EV Battery Temperature Sensor "A" Circuit Low |
- Temperature sensor x > 94° C
|
- Battery state HV OFF or Precharge or HV_ON or Emergency OFF
|
0.60 Sec |
|
| P0AC8 |
Hybrid/EV Battery Temperature Sensor "A" Circuit Low |
- Temperature sensor x > 94° C
|
- Battery state HV OFF or Precharge or HV_ON or Emergency OFF
|
0.60 Sec |
|
| P0ACB |
Hybrid/EV Battery Temperature Sensor "C" Circuit Range/Performance |
- difference of two temperature sensors < -20° C
OR
- difference of two temperature sensors > 20° C
- Number of checks with a single sensor exceeds threshold value >= 5
|
- Battery state HV OFF or Precharge or HV_ON
|
10 Sec |
|
| P0ACC |
Hybrid/EV Battery Temperature Sensor "A" Circuit Low |
- Temperature sensor x > 94° C
|
- Battery state HV OFF or Precharge or HV_ON or Emergency OFF
|
0.60 Sec |
|
| P0ABD |
Hybrid/EV Battery Pack Voltage Sense "A" Circuit High |
- Negative contactor voltage > 258 V
- or
- Negative contactor voltage < -258 V
- or
- Positive contactor voltage > 258 V
- or
- Positive contactor voltage < -258 V
|
|
0.10 Sec. |
|
| P0ACD |
Hybrid/EV Battery Temperature Sensor "A" Circuit Low |
- Temperature sensor x > 94° C
|
- Battery state HV OFF or Precharge or HV_ON or Emergency OFF
|
0.60 Sec |
|
| P0A9C |
Hybrid/EV Battery Temperature Sensor "A" Circuit Range/Performance |
- difference of two temperature sensors < -20° C
OR
- difference of two temperature sensors > 20° C
- Number of checks with a single sensor exceeds threshold value >= 5
|
- Battery state HV OFF or Precharge or HV_ON
|
10 Sec |
|
| P0AE2 |
Hybrid/EV Battery Precharge Contactor Circuit Stuck Closed |
- State 1: all contactors off inconsistency
- State 2: control negative contactor to close inconsistency
- State 3: control precharge contactor to close inconsistency
- State 4: control positive contactor to close inconsistency
- State 5: control precharge contactor to open in case of malfunction of state 1 to 5 to pin-point: inconsistency
- State 6: control negative contactor to open inconsistency
|
|
--- |
|
| P0AE3 |
Hybrid/EV Battery Precharge Contactor Circuit Stuck Open |
- State 1: all contactors off inconsistency
- State 2: control negative contactor to close inconsistency
- State 3: control precharge contactor to close inconsistency
- State 4: control positive contactor to close inconsistency
- State 5: control precharge contactor to open in case of malfunction of state 1 to 5 to pin-point: inconsistency
- State 6: control negative contactor to open inconsistency
|
|
--- |
|
| P0AE9 |
Hybrid/EV Battery Temperature Sensor "D" Circuit Range/Performance |
- difference of two temperature sensors < -20° C
OR
- difference of two temperature sensors > 20° C
- Number of checks with a single sensor exceeds threshold value >= 5
|
- Battery state HV OFF or Precharge or HV_ON
|
10 Sec |
|
| P0AEA |
Hybrid/EV Battery Temperature Sensor "A" Circuit Low |
- Temperature sensor x > 94° C
|
- Battery state HV OFF or Precharge or HV_ON or Emergency OFF
|
0.60 Sec |
|
| P0AEB |
Hybrid/EV Battery Temperature Sensor "A" Circuit Low |
- Temperature sensor x > 94° C
|
- Battery state HV OFF or Precharge or HV_ON or Emergency OFF
|
0.60 Sec |
|
| P0AF8 |
Hybrid/EV Battery System Voltage |
OR
- Positive Pack Voltage - Negative Pack Voltage < 48 V
- Positive Backup Pack Voltage - Negative Backup Pack Voltage < 48 V
|
- battery state: during precharge HV_ON (second check by voltage)
|
0.05 Sec |
|
| P0B15 |
Hybrid Battery Pack Voltage Sense "B" Circuit Range/Performance |
- State 1: all contactors off inconsistency
- State 2: control negative contactor to close inconsistency
- State 3: control precharge contactor to close inconsistency
- State 4: control positive contactor to close inconsistency
- State 5: control precharge contactor to open in case of malfunction of state 1 to 5 to pin-point: inconsistency
- State 6: control negative contactor to open inconsistency
|
|
2 to 5 Sec |
|
| P0B16 |
Hybrid/EV Battery Pack Voltage Sense "B" Circuit Low |
- (HVP - CVP) * 100 / HVP <= 20 %
OR
- (HVN - CVN) * 100 / HVN <= 20 %
|
|
0.10 Sec. |
|
| P0B17 |
Hybrid/EV Battery Pack Voltage Sense "B" Circuit High |
- Negative contactor voltage > 258 V
- or
- Negative contactor voltage < -258 V
- or
- Positive contactor voltage > 258 V
- or
- Positive contactor voltage < -258 V
|
|
0.10 Sec. |
|
| P0B15 |
Hybrid/EV Battery Pack Voltage Sense "B" Circuit Range/Performance |
- Negative contactor voltage > 1.15 V negative total cell voltage
- or
- Negative contactor voltage < 0.85 V negative total cell voltage
- or
- Positive contactor voltage > 1.15 V positive total cell voltage
- or
- Positive contactor voltage < 0.85 V positive total cell voltage V
|
|
1 Sec. |
|
| P0B3C |
Hybrid Battery Voltage Sense "A" Circuit Range/Performance |
- TV-High > 240 V
- TV-High < 24 V
- TV-High - HVP > 48 V
- TV-High - CVP > 48 V
- HVP - CVP < 48 V
|
|
1 to 5 Sec |
|
- Average Block voltage - Minimum Block voltage (8 cell) > 1.2 V
OR
- Minimum Block voltage (8 cell) - Minimum Block voltage (16 cell) > 0.6 V
|
- Battery state HV OFF or Precharge or HV_ON
|
10 Sec |
| P0B41 |
Hybrid/EV Battery Voltage Sense "B" Circuit Range/Performance |
- Block Voltage (TMV01) < 20.8 V
- Block Voltage (TMV01) > 208 V
|
- Battery state HV OFF or Precharge or HV_ON
|
2 Sec |
|
- Average Block voltage - Minimum Block voltage (8 cell) > 1.2 V
OR
- Minimum Block voltage (8 cell) - Minimum Block voltage (16 cell) > 0.6 V
|
- Battery state HV OFF or Precharge or HV_ON
|
10 Sec |
| P0B42 |
Hybrid/EV Battery Voltage Sense "B" Circuit Low |
- Block Voltage (TMV01) < -226 V
|
- Battery state HV OFF or Precharge or HV_ON
|
1 Sec |
|
| P0B43 |
Hybrid/EV Battery Voltage Sense "B" Circuit High |
- Block Voltage (TMV01) > 226 V
|
- Battery state HV OFF or Precharge or HV_ON
|
1 Sec |
|
| P0B46 |
Hybrid/EV Battery Voltage Sense "C" Circuit Range/Performance |
- Block Voltage (TMV02) < 17.6 V
- Block Voltage (TMV02) > 176 V
|
- Battery state HV OFF or Precharge or HV_ON
|
2 Sec |
|
- Average Block voltage - Minimum Block voltage (8 cell) > 1.2 V
OR
- Minimum Block voltage (8 cell) - Minimum Block voltage (16 cell) > 0.6 V
|
- Battery state HV OFF or Precharge or HV_ON
|
10 Sec |
| P0B47 |
Hybrid/EV Battery Voltage Sense "C" Circuit Low |
- Block Voltage (TMV02) < -189 ]
|
- Battery state HV OFF or Precharge or HV_ON
|
1 Sec |
|
| P0B48 |
Hybrid/EV Battery Voltage Sense "C" Circuit High |
- Block Voltage (TMV02) > 189 V
|
- Battery state HV OFF or Precharge or HV_ON
|
1 Sec |
|
| P0B4B |
Hybrid/EV Battery Voltage Sense "D" Circuit Range/Performance |
- Block Voltage (TMV03) < 14.4 V
- Block Voltage (TMV03) > 144 [V
|
- Battery state HV OFF or Precharge or HV_ON
|
2 Sec |
|
- Average Block voltage - Minimum Block voltage (8 cell) > 1.2 V
OR
- Minimum Block voltage (8 cell) - Minimum Block voltage (16 cell) > 0.6 V
|
- Battery state HV OFF or Precharge or HV_ON
|
10 Sec |
| P0B4C |
Hybrid/EV Battery Voltage Sense "D" Circuit Low |
- Block Voltage (TMV03) < -171 V
|
- Battery state HV OFF or Precharge or HV_ON
|
1 Sec |
|
| P0B4D |
Hybrid/EV Battery Voltage Sense "D" Circuit High |
- Block Voltage (TMV03) > 171 V
|
- Battery state HV OFF or Precharge or HV_ON
|
1 Sec |
|
| P0B50 |
Hybrid/EV Battery Voltage Sense "E" Circuit Range/Performance |
- Block Voltage (TMV04) < 11.2 V
- Block Voltage (TMV04) > 112 V
|
- Battery state HV OFF or Precharge or HV_ON
|
2 Sec |
|
- Average Block voltage - Minimum Block voltage (8 cell) > 1.2 V
OR
- Minimum Block voltage (8 cell) - Minimum Block voltage (16 cell) > 0.6 V
|
- Battery state HV OFF or Precharge or HV_ON
|
10 Sec |
| P0B51 |
Hybrid/EV Battery Voltage Sense "E" Circuit Low |
- Block Voltage (TMV04) < -171V
|
- Battery state HV OFF or Precharge or HV_ON
|
1 Sec |
|
| P0B52 |
Hybrid/EV Battery Voltage Sense "E" Circuit High |
- Block Voltage (TMV04) > 171 V
|
- Battery state HV OFF or Precharge or HV_ON
|
1 Sec |
|
| P0B55 |
Hybrid/EV Battery Voltage Sense "F" Circuit Range/Performance |
- Block Voltage (TMV05) < 8 V
- Block Voltage (TMV05) > 80 V
|
- Battery state HV OFF or Precharge or HV_ON
|
2 Sec |
|
- Average Block voltage - Minimum Block voltage (8 cell) > 1.2 V
OR
- Minimum Block voltage (8 cell) - Minimum Block voltage (16 cell) > 0.6 V
|
- Battery state HV OFF or Precharge or HV_ON
|
10 Sec |
| P0B56 |
Hybrid/EV Battery Voltage Sense "F" Circuit Low |
- Block Voltage (TMV05) < -189 V
|
- Battery state HV OFF or Precharge or HV_ON
|
1 Sec |
|
| P0B57 |
Hybrid/EV Battery Voltage Sense "F" Circuit High |
- Block Voltage (TMV05) > 189 V
|
- Battery state HV OFF or Precharge or HV_ON
|
1 Sec |
|
| P0B5A |
Hybrid/EV Battery Voltage Sense "G" Circuit Range/Performance |
- Block Voltage (TMV06) < 4.8 V
- Block Voltage (TMV06) > 48 V
|
- Battery state HV OFF or Precharge or HV_ON
|
2 Sec |
|
- Average Block voltage - Minimum Block voltage (8 cell) > 1.2 V
OR
- Minimum Block voltage (8 cell) - Minimum Block voltage (16 cell) > 0.6 V
|
- Battery state HV OFF or Precharge or HV_ON
|
10 Sec |
| P0B5B |
Hybrid/EV Battery Voltage Sense "G" Circuit Low |
- Block Voltage (TMV06) < -192 V
|
- Battery state HV OFF or Precharge or HV_ON
|
1 Sec |
|
| P0B5C |
Hybrid/EV Battery Voltage Sense "G" Circuit High |
- Block Voltage (TMV06) > 192 V
|
- Battery state HV OFF or Precharge or HV_ON
|
1 Sec |
|
| P0B5F |
Hybrid/EV Battery Voltage Sense "H" Circuit Range/Performance |
- Block Voltage (TMV07) < 1.6 V
- Block Voltage (TMV07) > 16 V
|
- Battery state HV OFF or Precharge or HV_ON
|
1 Sec |
|
- Average Block voltage - Minimum Block voltage (8 cell) > 1.2 V
OR
- Minimum Block voltage (8 cell) - Minimum Block voltage (16 cell) > 0.6 V
|
- Battery state HV OFF or Precharge or HV_ON
|
10 Sec |
| P0B60 |
Hybrid/EV Battery Voltage Sense "H" Circuit Low |
- Block Voltage (TMV07) < -192 V
|
- Battery state HV OFF or Precharge or HV_ON
|
1 Sec |
|
| P0B61 |
Hybrid/EV Battery Voltage Sense "H" Circuit High |
- Block Voltage (TMV07) > 192 V
|
- Battery state HV OFF or Precharge or HV_ON
|
1 Sec |
|
| P0BC3 |
Hybrid/EV Battery Temperature Sensor "E" Circuit Range/Performance |
- difference of two temperature sensors < -20° C
OR
- difference of two temperature sensors > 20° C
- Number of checks with a single sensor exceeds threshold value >= 5
|
- Battery state HV OFF or Precharge or HV_ON
|
10 Sec |
|
| P0BC4 |
Hybrid/EV Battery Temperature Sensor "A" Circuit Low |
- Temperature sensor x > 94° C
|
- Battery state HV OFF or Precharge or HV_ON or Emergency OFF
|
0.60 Sec |
|
| P0BC5 |
Hybrid/EV Battery Temperature Sensor "A" Circuit Low |
- Temperature sensor x > 94° C
|
- Battery state HV OFF or Precharge or HV_ON or Emergency OFF
|
0.60 Sec |
|
| P0BC8 |
Hybrid/EV Battery Pack Cooling Fan 1Sense Range/Performance |
- fan feedback voltage > 1.37 to 3.43 V (depending on fan duty)
|
- Battery state HV OFF or Precharge or HV_ON
- minimum fan speed > 30% fan duty
|
30 Sec |
|
| P0BC9 |
Hybrid/EV Battery Pack Cooling Fan 1 Sense Circuit Low |
- Fan feedback voltage < 0.1 V
|
- Battery state HV OFF or Precharge or HV_ON
- minimum fan speed > 30% fan duty
|
10 Sec |
|
| P0BCA |
Hybrid/EV Battery Pack Cooling Fan 1 Sense Circuit High |
- Fan feedback voltage > 3.45 V
|
- Battery state HV OFF or Precharge or HV_ON
- minimum fan speed > 30% fan duty
|
10 Sec |
|
| P0C34 |
Hybrid/EV Battery Temperature Sensor "F" Circuit Range/Performance |
- difference of two temperature sensors < -20° C
OR
- difference of two temperature sensors > 20° C
- Number of checks with a single sensor exceeds threshold value >= 5
|
- Battery state HV OFF or Precharge or HV_ON
|
10 Sec |
|
| P0C35 |
Hybrid/EV Battery Temperature Sensor "A" Circuit Low |
- Temperature sensor x > 94° C
|
- Battery state HV OFF or Precharge or HV_ON or Emergency OFF
|
0.60 Sec |
|
| P0C36 |
Hybrid/EV Battery Temperature Sensor "A" Circuit Low |
- Temperature sensor x > 94° C
|
- Battery state HV OFF or Precharge or HV_ON or Emergency OFF
|
0.60 Sec |
|
| P0DAC |
Hybrid/EV Battery Cell Balancing Circuit "A" |
- Cell voltage direction different count >= 9 counts
- or
- cell voltage > 4 mV
- or
- cell voltage < 4 mV
- or
- cell voltage - 1.85 V > 0.8 V
|
- Battery state HV OFF or Precharge or HV_ON or Emergency OFF
- and
- Drive motor revolution < 20 RPM
- and
- Electric drive motor current < 20 A
- Battery state INIT
|
Immediate |
|
| P0DB0 |
Hybrid/EV Battery Cell Balancing Circuit "B" |
- Cell voltage direction different count >= 9 counts
- or
- cell voltage > 4 mV
- or
- cell voltage < 4 mV
- or
- cell voltage - 1.85 V > 0.8 V
|
- Battery state HV OFF or Precharge or HV_ON or Emergency OFF
- and
- Drive motor revolution < 20 RPM
- and
- Electric drive motor current < 20 A
- Battery state INIT
|
Immediate |
|
| P0DB4 |
Hybrid/EV Battery Cell Balancing Circuit "C" |
- Cell voltage direction different count >= 9 counts
- or
- cell voltage > 4 mV
- or
- cell voltage < 4 mV
- or
- cell voltage - 1.85 V > 0.8 V
|
- Battery state HV OFF or Precharge or HV_ON or Emergency OFF
- and
- Drive motor revolution < 20 RPM
- and
- Electric drive motor current < 20 A
- Battery state INIT
|
Immediate |
|
| P0DB8 |
Hybrid/EV Battery Cell Balancing Circuit "D" |
- Cell voltage direction different count >= 9 counts
- or
- cell voltage > 4 mV
- or
- cell voltage < 4 mV
- or
- cell voltage - 1.85 V > 0.8 V
|
- Battery state HV OFF or Precharge or HV_ON or Emergency OFF
- and
- Drive motor revolution < 20 RPM
- and
- Electric drive motor current < 20 A
- Battery state INIT
|
Immediate |
|
| P0DBC |
Hybrid/EV Battery Cell Balancing Circuit "E" |
- Cell voltage direction different count >= 9 counts
- or
- cell voltage > 4 mV
- or
- cell voltage < 4 mV
- or
- cell voltage - 1.85 V > 0.8 V
|
- Battery state HV OFF or Precharge or HV_ON or Emergency OFF
- and
- Drive motor revolution < 20 RPM
- and
- Electric drive motor current < 20 A
- Battery state INIT
|
Immediate |
|
| P0DC0 |
Hybrid/EV Battery Cell Balancing Circuit "F" |
- Cell voltage direction different count >= 9 counts
- or
- cell voltage > 4 mV
- or
- cell voltage < 4 mV
- or
- cell voltage - 1.85 V > 0.8 V
|
- Battery state HV OFF or Precharge or HV_ON or Emergency OFF
- and
- Drive motor revolution < 20 RPM
- and
- Electric drive motor current < 20 A
- Battery state INIT
|
Immediate |
|
| P0DC4 |
Hybrid/EV Battery Cell Balancing Circuit "G" |
- Cell voltage direction different count >= 9 counts
- or
- cell voltage > 4 mV
- or
- cell voltage < 4 mV
- or
- cell voltage - 1.85 V > 0.8 V
|
- Battery state HV OFF or Precharge or HV_ON or Emergency OFF
- and
- Drive motor revolution < 20 RPM
- and
- Electric drive motor current < 20 A
- Battery state INIT
|
Immediate |
|
| P0DC8 |
Hybrid/EV Battery Cell Balancing Circuit "H" |
- Cell voltage direction different count >= 9 counts
- or
- cell voltage > 4 mV
- or
- cell voltage < 4 mV
- or
- cell voltage - 1.85 V > 0.8 V
|
- Battery state HV OFF or Precharge or HV_ON or Emergency OFF
- and
- Drive motor revolution < 20 RPM
- and
- Electric drive motor current < 20 A
- Battery state INIT
|
Immediate |
|