CLIMATRONIC Control Module Multi-Pin Harness Connector
Special tools and workshop equipment required
- Test Box -V.A.G 1598/42-
- Adapter Cable -V.A.G 1598/47-
- Template -V.A.G 1598/47-2-
20-pin Harness Connector -A-, T20c
1 - Sunlight Photo Sensor 2 -G134- or Sunlight Photo Sensor -G107-, signal
2 - High Pressure Sensor -G65-
3 - Sunlight Photo Sensor 2 -G134- or Sunlight Photo Sensor -G107-, signal
4 - Air Quality Sensor -G238- (not for the North American markets)
5 - CAN bus high
6 - CAN bus low
7 - Indirect Ventilation Door Motor -V213- (not for the North American markets)
8 - Indirect Ventilation Door Motor -V213- (not for the North American markets)
9 - + 5V for Sunlight Photo Sensor 2 -G134- or Sunlight Photo Sensor -G107-
10 - Heated Driver Seat Temperature Sensor -G59- or Front Seat Heating Control Module -J774- (optional)
11 - Front Passenger Heated Seat Temperature Sensor -G60- or Front Seat Heating Control Module -J774- (optional)
12 - Terminal 75 (optional)
13 - Left Vent Temperature Sensor -G150-
14 - Right Vent Temperature Sensor -G151-
15 - Indirect Ventilation Door Motor Position Sensor -G330- (not for the North American markets)
16 - Terminal 30a/without auxiliary heater terminal 15
17 - Signal ground for Sunlight Photo Sensor (3241) -G107-, Sunlight Photo Sensor 2 -G134-, Left Vent Temperature Sensor -G150-, Right Vent Temperature Sensor -G151- and Indirect Ventilation Flap Motor -V213-
18 - A/C Compressor Regulator Valve -N280-
19 - Terminal 31
20 - Terminal 30a / without auxiliary heater terminal 15
16-pin Harness Connector -B-, T16i
1 - + 5V for motors
2 - Left Temperature Door Potentiometer/Actuator -G220-
3 - Right Temperature Door Potentiometer/Actuator -G221-
4 - Defroster Door Motor Position Sensor -G135-
5 - Front air distribution flap motor position sensor -G642-
6 - Recirculation Door Motor Position Sensor -G143-
7 - Fresh Air/Recirculating Air/Back Pressure Flap Motor Position Sensor -G644-
8 - Left Footwell Vent Temperature Sensor -G261-
9 - Right Footwell Vent Temperature Sensor -G262-
11 - Evaporator Temperature Sensor -G308-
14 - Signal Ground (GND) potentiometer
16-pin Harness Connector -C-, T16h
1 - Left Temperature Door Motor -V158-, cold
2 - Left Temperature Door Motor -V158-, warm
3 - Defroster Door Motor -V107-, closed
4 - Defroster Door Motor -V107-, open
5 - Front air distribution flap motor -V426-, upper body outlet
6 - Front air distribution flap motor -V426-, footwell
7 - Recirculation Door Motor -V113-
8 - Recirculation Door Motor -V113-
9 - Fresh Air/Recirculating Air/Back Pressure Flap Motor -V425-, open
10 - Fresh Air/Recirculating Air/Back Pressure Flap Motor -V425-, closed
11 - Right temperature door motor -V159-, cold
12 - Right Temperature Door Motor -V159-, warm
15 - Fresh Air Blower Control Module -J126-
16 - Control Module For Fresh Air Blower -J126-, signal