| P0604 |
Internal Control Module Random Access Memory (RAM) Error |
- CAN-transceiver RAM failure
|
--- |
--- |
|
| P064F |
Unauthorized Software/Calibration Detected |
- Internal eprom value is not plausible
|
--- |
--- |
|
| P06B1 |
Sensor Power Supply "A" Circuit Low |
- Power supply voltage = ground
|
--- |
800 ms |
|
| P06B2 |
Sensor Power Supply "A" Circuit High |
- Power supply voltage = battery voltage
|
--- |
800 ms |
|
| P06B4 |
Sensor Power Supply "B" Circuit Low |
- Power supply voltage too low
|
--- |
50 ms |
|
| P06B5 |
Sensor Power Supply "B" Circuit High |
- Power supply voltage too high
|
--- |
50 ms |
|
| P06B0 |
Sensor Power Supply "A" Circuit/Open |
- VDD5 supply voltage too high internal hardware check
|
--- |
--- |
|
| P06B5 |
Sensor Power Supply "B" Circuit High |
- Gate driver internal hardware check = battery voltage
|
|
800 ms |
|
| P0A1B |
Drive Motor "A" Control Module |
- DC link circuit resistance < 0, 19 [Ohm] (= DC link voltage / DC link current)
|
DC link current > 50 A |
10 ms |
|
| P0A2B |
Drive Motor "A" Temperature Sensor Circuit Range/Performance |
|
|
--- |
|
| P0A2C |
Drive Motor "A" Temperature Sensor Circuit Low |
|
|
1000 ms |
|
| P0A2D |
Drive Motor "A" Temperature Sensor Circuit High |
|
|
1000 ms |
|
| P0A40 |
Drive Motor "A" Position Sensor Circuit Range/Performance |
- Signal pattern change too fast < 100 μs
|
- Drive motor speed > 100 for 1 min and/or < 2000 for 1 min
|
100 ms |
|
| P0AEE |
Drive Motor Inverter Temperature Sensor "A" Circuit Range/Performance |
- Phase U IGBT temperature too low > 5 K
|
|
--- |
|
| P0AEF |
Drive Motor Inverter Temperature Sensor "A" Circuit Low |
- Phase U IGBT temperature too low < - 55 °C
|
|
800 ms |
|
| P0AF0 |
Drive Motor Inverter Temperature Sensor "A" Circuit High |
- Phase U IGBT temperature too high > 161 [°C]
|
|
800 ms |
|
| P0AF3 |
Drive Motor Inverter Temperature Sensor "B" Circuit Range/Performance |
- Phase V IGBT temperature - Phase U IGBT temperature > 5 K
|
Engine off time > 6 h |
--- |
|
| P0AF4 |
Drive Motor Inverter Temperature Sensor "B" Circuit Low |
- Phase V IGBT temperature too low < - 57 °C
|
|
800 ms |
|
| P0AF5 |
Drive Motor Inverter Temperature Sensor "B" Circuit High |
- Phase V IGBT temperature too high > + 161 °C
|
|
800 ms |
|
| P0BD2 |
Drive Motor Inverter Temperature Sensor "C" Circuit Range/Performance |
- Phase W IGBT temperature - Phase W IGBT temperature > 5 K
|
Engine off time > 6 h |
--- |
|
| P0BD3 |
Drive Motor Inverter Temperature Sensor "C" Circuit Low |
- Phase W IGBT temperature too low < - 57 °C
|
|
800 ms |
|
| P0BD4 |
Drive Motor Inverter Temperature Sensor "C" Circuit High |
- Phase W IGBT temperature too high > + 161 °C
|
|
800 ms |
|
| P0BE6 |
Drive Motor "A" Phase U Current Sensor Circuit Range/Performance |
- Phase U current offset > 20 A
|
- System state: Init
- System state: Drive
- Drive motor speed > 500 1/min and / or < 4000 1/min
|
2000 ms |
|
| P0BE7 |
Drive Motor "A" Phase U Current Sensor Circuit Low |
- Phase U current negative value too high < - 928 A
|
--- |
800 ms |
|
| P0BEA |
Drive Motor "A" Phase V Current Sensor Circuit Range/Performance |
- Phase V current offset > 23 A
|
- Drive motor speed > 500 1/min and / or < 4000 1/min
|
800 ms |
|
| P0BEB |
Drive Motor "A" Phase V Current Sensor Circuit Low |
- Phase V current negative value too high < -921 A
|
--- |
800 ms |
|
| P0BEC |
Drive Motor "A" Phase V Current Sensor Circuit High |
- Phase V current positive value too high > 921 A
|
--- |
2000 ms |
|
| P0BE8 |
Drive Motor "A" Phase U Current Sensor Circuit High |
- Phase U current positive value too high > 921 A
|
--- |
800 ms |
|
| P0BEE |
Drive Motor "A" Phase W Current Sensor Circuit Range/Performance |
- Phase W current offset > 23 A
|
- Drive motor speed > 500 1/min and / or < 4000 1/min]
|
800 ms |
|
| P0BEF |
Drive Motor "A" Phase W Current Sensor Circuit Low |
- Phase W current negative value too high < -921 A
|
--- |
800 ms |
|
| P0BF0 |
Drive Motor "A" Phase W Current Sensor Circuit High |
- Phase W current positive value too high > 921 A
|
--- |
2000 ms |
|
| P0BFD |
Drive Motor "A" Phase U-V-W Current Sensor Correlation |
- Phase U + Phase V + Phase W > 40 A]
|
- Drive motor speed > 600 for 1 min and/or < 4125 for 1 min
|
1000 ms |
|
| P0BFF |
Drive Motor "A" Current |
- Calculated drive motor voltage - drive motor model voltage > 100 V
|
|
1000 ms |
|
| P0C01 |
Drive Motor "A" Current High |
- Phase U, V, W signal range check > 745 A
|
|
--- |
|
| P0C17 |
Drive Motor "A" Position Sensor Not Learned |
- Offset angle estimation < - 200 [1/min]
|
System state: Offset angle calibration |
--- |
|
- Offset angle deviation > 60°
|
| P0C4E |
Drive Motor "A" Position Exceeded Learning Limit |
- incorrect order of signal change from position sensor = wrong order
|
System state: Offset angle calibration |
--- |
|
- Time for acceleration to long > 2, 5 [s]
|
- Drive motor speed while acceleration > 1750 [1/min]
|
|
|
System state: offset angle calibration and active freewheeling |
- Time to calculate offset angle > 0, 5 [s]
|
System state: Offset angle calibration |
| P0C51 |
Drive Motor "A" Position Sensor Circuit "A" Range/Performance |
- Position sensor signal out of range low or high
|
--- |
100 ms |
|
| P0C52 |
Drive Motor "A" Position Sensor Circuit "A" Low |
- Position sensor signal < 0.064 V
|
--- |
10 ms |
|
| P0C53 |
Drive Motor "A" Position Sensor Circuit "A" High |
- Position sensor signal > 4.889 V
|
--- |
10 ms |
|
| P0C5B |
Drive Motor "A" Position Sensor Circuit "B" Range/Performance |
- Position sensor signal out of range low or high
|
--- |
100 ms |
|
| P0C5C |
Drive Motor "A" Position Sensor Circuit "B" Low |
- Position sensor signal = 0 (continuously) -
|
--- |
10 ms |
|
| P0C5D |
Drive Motor "A" Position Sensor Circuit "B" High |
- Position sensor signal = 1 (continuously) -
|
--- |
10 ms |
|
| P0C79 |
Drive Motor "A" Inverter Voltage Too High |
|
--- |
800 ms |
|
| P0D2E |
Drive Motor "A" Inverter Voltage Sensor Circuit Range/Performance |
- DC link voltage (BECM) - DC link voltage (DMCM) > 9 to 24 V
|
DC link voltage (BECM) signal valid - |
800 ms |
|
| P0D30 |
Drive Motor "A" Inverter Voltage Sensor Circuit High |
- DC link voltage too high > 440 V
|
|
800 ms |
|
| P33CA |
Power electronics control module wrong software version |
- Internal failure detection
|
|
|
|
| P33D4 |
Drive motor "A" magnetic flow calibration implausible |
- Deviation of measured magnetic flux from nominal magnetic flux > 25 %
|
- Offset angle calibration active
- and
- difference between inverter temperature model and drive motor stator temperature < 30 K
|
|
|
| P33D7 |
Control module for power electronic, output module 1 Internal malfunction |
- IGBT module hardware check - Internal failure detection
|
|
|
|
| P33D8 |
Control module for power electronic, output module 2 Internal malfunction |
- IGBT module hardware check - Internal failure detection
|
|
|
|
| P33D9 |
Control module for power electronic, HV input current Implausible |
- DC link current (BECM) + (DC link current (DMCM) + 20A > 50 A
|
- Drive motor speed > 0 and < 6800
|
600 ms |
|
| P33DA |
Control module for power electronic software or hardware version, implausible |
Internal failure detection |
|
|
|