Pin Assignment, Electrical Manual Climate Control Unit, From May 29, 2011
Special tools and workshop equipment required
- Basic Test Box -V.A.G 1598/14-
- Test Adapter -V.A.G 1598/47-
- Template -V.A.G 1598/47-2-
Fig 1: Identifying 5-Pin Connector -A- In Wiring Diagram T5 And 16-Pin Connector -B- In Wiring Diagram T16e
5-pin Harness Connector -A- in Wiring Diagram T5
1 - 3rd Blower Speed
2 - 2nd Blower Speed
3 - 1st Blower Speed
4 - 4th Blower Speed
5 - Terminal X
16-pin Harness Connector -B- in Wiring Diagram T16e
1 - Temperature regulator door motor -V68-, warm
2 - Evaporator temperature sensor -G308-
3 - Air distribution door motor position sensor -G645-
5 - Temperature regulator door motor position sensor -G92-
7 - +5V
8 - Ground signal
9 - Recirculation door motor -V113- set to open
10 - Recirculation door motor -V113- set to closed
11 - Temperature door motor -V68- - set to cold
12 - Air distribution door motor -V428-, set to position 1
13 - Air distribution door motor -V428-, set to position 2