Home >> Volkswagen >> 2013 >> Beetle Turbo, 2D Convertible, 2.0L Eng VIN A, Standard Trans >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> 2.0L - Generic Scan Tool - Engine Code: CBFA (Convertible) >> St Generic Scan Tool >> Diagnosis And Testing >> Diagnostic Procedures >> Heated Oxygen Sensor After Three Way Catalytic Converter, Checking
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Heated Oxygen Sensor After Three Way Catalytic Converter, Checking

NOTE:

Vehicle must be raised before the electrical connector for theOxygen Sensor After Three Way Catalytic Converter -G130- is accessible.

When servicing terminals in the electrical harness connector, use only gold-plated terminals.

Special tools and workshop equipment required 

Test requirements 

Test procedure 

-- Perform a preliminary check to verify the customers complaint. Refer to PRELIMINARY CHECK 

Start diagnosis 

-- Connect scan tool.

-- Start the engine and let it run at idle.

-- Select "Diagnostic mode 6: Check test results of components that are not continuously monitored".

-- Select "Monitor-ID 02: Oxygen sensor monitoring behind catalytic converter".

-- Select following Test-IDs.

-- Check the specified values at idle and compare the results to the min/max values given in the Mode 6 table.

If the specified values were obtained:

-- Switch ignition Off. Fault is not active at this time. Check for poor connections, loose terminals and harness check.

If the specified values were Not obtained:

-- Remove the right vehicle floor cover -arrows-.

Checking primary voltage

-- Disconnect the Oxygen Sensor After Three Way Catalytic Converter -G130- electrical harness connector -arrow-.

Fig 1: Disconnecting Connector For Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) G130
GWWA26-10132Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.

-- Switch the ignition On.

-- Using a multimeter, check the Oxygen Sensor After Three Way Catalytic Converter -G130- electrical harness connector terminals 3 to 4 for voltage.

Specified value: 0.400 to 0.500 Volts

-- Switch the ignition Off.

If the specified value was obtained:

-- Replace the Oxygen Sensor After Three Way Catalytic Converter -G130-. Refer to the Repair Service Information.

If the specified value was Not obtained:

Checking wiring 

-- Remove the Engine Control Module (ECM) -J623-. Refer to the Repair Service Information.

-- Using a multimeter, check the Oxygen Sensor After Three Way Catalytic Converter -G130- electrical harness connector terminals to the Engine Control Module (ECM) -J623- electrical harness connector T94 terminals for an open circuit according to the chart below.

Oxygen Sensor After Three Way Catalytic Converter -G130- electrical harness connector terminal: Engine Control Module (ECM) -J623- electrical connector T94 terminal:
3 33
4 84

Specified value: 1.5 Ω Max.

If the specified value was Not obtained:

-- Check the wiring for an open, high resistance or short to ground.

-- Check the electrical harness connector for damage, corrosion, loose or broken terminals.

-- If necessary, repair the faulty wiring connection.

If no malfunction is found in the wiring and the voltage was NOT present:

-- Replace the Engine Control Module (ECM) -J623-. Refer to the Repair Service Information.

-- Install the right vehicle floor cover -arrows-.

Final procedures 

After the repair work, the following work steps must be performed in the following sequence:

  1. Check the DTC memory. Refer to DIAGNOSTIC MODE 03 - READ DTC MEMORY .
  2. If necessary, erase the DTC memory. Refer to DIAGNOSTIC MODE 04 - ERASE DTC MEMORY .
  3. If the DTC memory was erased, generate readiness code. Refer to READINESS CODE .