MULTIFUNCTION Transmission Range Switch, Adjusting
Special tools and workshop equipment required
- Setting Gauge T10173
-- Move the selector lever into the "N" position.
-- Do not bend the selector lever cable.
Adjustment Prerequisites
- The selector lever cable is disconnected from the selector shaft lever.
- The selector shaft is in the "N" position.
- The bolts for the multifunction transmission range switch have been loosened.
- The lever is removed from the selector shaft.
-- Install the setting gauge onto the selector shaft -2- and turn the switch -1- just until the setting gauge locks onto the tab on the switch connection.
-- Use the thumb screw -3- to secure the setting gauge to the selector shaft -2-.
-- Tighten the switch bolts -arrows- to 6 Nm.
-- Remove the setting gauge.
-- Further installation is performed in the reverse order of removal. Refer to MULTIFUNCTION TRANSMISSION RANGE SWITCH F125 .