Test Step 7 - Liftgate Full Open Switch Sense Circuit Short to Logic Ground
- Measure the resistance between the liftgate full open switch sense circuit and the logic ground circuit in the power liftgate drive unit harness connector.
Is the resistance less than 10k ohms?
Yes
- Repair the liftgate full open switch sense circuit for a short to the ground.
- Perform the Body Verification Test. Refer to BODY VERIFICATION TEST .
No
- Go to Test Step 8 Test Step 8 - Liftgate Full Open Switch Sense Circuit Open