Test Step 2 - Liftgate Open Driver Circuit Short to Ground
- Turn the ignition OFF.
- Disconnect the power liftgate module C1 harness connector.
- Measure the resistance between ground and the liftgate open driver circuit.
Is the resistance less than 10k ohms?
Yes
- Go to Test Step 4 Test Step 4 - Liftgate Open Driver Wire Short to Ground
No